39
(10) Spill Containment Cleaning/Inspection
WARNING : INJURY
Do not lift up the unit using tie downs. Use of such could result in the generator falling.
No persons should ever be under a lifted generator.
CAUTION : INJURY
Always be sure to use lifting hooks when lifting up the generator, and raise it
slowly at a completely vertical angle.
Personnel performing lifting work must wear protective gear such as helmets,
safety shoes and gloves.
Do not move the generator during operation.
Clean
Every 500 hours
Separate the spill containment from this generator to clean and inspect the spill containment.
Spill Containment Separate/Reassemble
Disconnect the wiring connector.
Remove the seven spill containment fixing bolts (M8, 7 pieces).
Lift the generator, separate the spill containment and set the generator on a flat surface.
After cleaning and inspecting the inside of the spill containment, reverse the procedure
above for re-assembly.
Reassemble the fuel piping and wiring connector to their original positions.
< Note >
Do not operate the generator while separating.
Spill Containment Cleaning/Inspection
Use a high-pressure cleaner or similar equipment to clean the inside of the spill
containment.
Remove the drain plug (R1/2) to drain the cleaning water and open the drain valve lever.
Check that there no rust has developed inside of the spill containment. If rust has
developed, remove the rust and clean again.
Close the drain valve lever.
1
Drain Plug(R1/2)
Drain Valve Lever
5
Drain Valve
Drain Plug
(R1/2)
Loosen
Tighten
Close
Close
Open
Drain Valve
Drain Valve
Lever
2
3
4
1
2
4
3
Содержание DGK15F
Страница 2: ......
Страница 49: ...46 aaaaaa 13 Generator Circuit Diagram...
Страница 50: ...47 aaaaaa 14 Engine Electrical Circuit Diagram...
Страница 51: ......
Страница 52: ...2019...