Switch Selection
“L1+U”: Three-phase L1 phase + Single-phase three-wire U phase (total)
“L2”: Three-phase L2 phase
“L3+W”: Three-phase L3 phase + Single-phase three-wire W phase (total)
< Note >
If measuring the output current for a single-phase three-wire type, turn the ammeter selector
switch to “L1+U” or “L3+W”. The voltage cannot be accurately measured if set to “L2”.
Voltage Regulator
(1) Voltage Regulator
This dial is for regulating voltage output by the generator. Turn the
dial clockwise to increase the voltage and counterclockwise to
decrease it.
6.
Transport/Installation
6-1. Transport Procedures
WARNING : INJURY
Do not lift up the unit using tie down. Use of such could result in the generator falling.
No persons should ever be under a lifted generator.
CAUTION : INJURY
Always be sure to use lifting hooks when lifting up the generator, and raise it
slowly at a completely vertical angle.
Personnel performing lifting work must wear protective gears such as helmets,
safety shoes and gloves.
Do not move the generator during operation.
(1) Lifting Procedures
Always be sure to use lifting hooks when lifting up the generator, and raise it slowly at a
completely vertical angle.
(2) Transport
When transporting this generator, tie rope to the left and right tie downs, and securely fix the
generator.
Tie-Down
Lifting