
200-33168
Seal Teflon
As required
Consumable
036-15550-12
Oring,AS568A-012 4D
As required
Consumable
225-09344
Sample vacuum bottle
As required
Consumable
225-04209
cap
As required
Consumable
225-10627-91
DI PROBE ASSY
As required
Consumable
DI
225-10618-91
REPELLER2,CI+(C)
IN DI mode ,CI analysis
As required
Consumable
225-09493-03
STANDARD SAMPLE (PFTBA) 5g
As required
Consumable
STANDAR
DSAMPLE 225-09493-01
STANDARD SAMPLE (TRIAZINE) 0.5g
As required
Consumable
Consumable
VACUM
SYSTEM
017-30163-11
ROTARY PUMP OIL ULTRAGRADE15 1L
0.28L per oil replacement
1L/year (#5)
Consumable
085-35124-03
SCOTCHBRITE (for finishing electrodes) set of 20 sheets
20 sheets/year
225-10194-91
JIG, IS
Service part
225-01453-94
COLUMN MOUNTING JIG (I/F)
Tools and
jigs
225-01453-95
COLUMN MOUNTING JIG (INJ)
#1 Replace after approximately 80 injections.
#2 If carrier gas leaks or when glass insert is replaced.
#3
Replace periodically, normally once every 6 months. However, replace more frequently under
certain measurement conditions or after many analyses of samples with a high boiling-point or
samples that are solid at room temperature.
(See GC System User Guide for details.)
#4 Use when column is replaced.
#5 Ideally, replace oil once every three months (3000 hours operating time). Insufficient vacuum can cause various problems in the
mass spectrometer system. The oil must be replaced appropriately.
Содержание GCMS-QP2010 Series
Страница 1: ...1 225 00612A Gas Chromatograph Mass Spectrometer GCMS QP2010 Service Manual...
Страница 14: ...14 Do not increase the ion source or interface temperature above the level required for analysis...
Страница 27: ...27...
Страница 71: ...71 Wiring Diagrams 1 Wiring diagram Overall Wiring Diagrams...
Страница 72: ...72 Wiring Diagrams 2 Wiring diagram MAIN POWER ASSY...
Страница 73: ...73 Unit Operation Checks 3 Wiring diagram Details...
Страница 76: ...76 MAIN POWER ASSY Block Diagram Parts inside the broken box are in the MAIN POWER ASSY...
Страница 79: ...79 DC POWER A Block Diagram...
Страница 84: ...84 MAIN CTRL A Block Diagram...
Страница 85: ...85...
Страница 90: ...90 IS CTRL A Block Diagram...
Страница 94: ...94 HV PCB ASSY block diagram 1 UNNCI case of model EI CI 2 NCI case of model NCI...
Страница 98: ...98 IG CTRL A PCB Block Diagram...
Страница 103: ...103 CP6 24V normal range 22 7 to 25 3VDC CP7 24V normal range 22 7 to 25 3VDC CP12 5V normal range 4 8 to 5 3VDC...
Страница 109: ...109 DI CTRL A block diagram...
Страница 145: ...121 5 Remove the IS CTRL A Board Unit Disconnect the two connectors Remove the three screws and the spacer screw...
Страница 150: ...126 Do not remove the 2 screws on the right side Remove the 2 screws on the left side...
Страница 151: ...127 Remove cardboard Move the TW300 left by holding in both hands...
Страница 154: ...130 10 Preparation of new TW300 New TW 300 Removed TW300 Check the name plate Old type New type...
Страница 155: ...131 Remove the cap of outlet Loosen the 3 fixing screws and remove the plate Remove the o ring...
Страница 158: ...134 Hook the right side hooks on the neck of inlet Attach the left side screws and hooks Fasten lightly the 4 screws...
Страница 160: ...136 Remove the cardboard Completion of TMP mounting...
Страница 161: ...137 12 Fix the flange to outlet Place the flange on the outlet Do not forget to place o ring...
Страница 163: ...139 Slide fast the IS CTRL A board down and fix it 4 screws Connect the two connectors...
Страница 164: ...140 14 Place the covers Place the front cover Place the front door...