5-10
VL-E610S/VL-E610H
VL-E660S/VL-E96E
VL-E98E
1) Input the audio signal (400Hz, -8dBs) into the Audio line
IN/OUT terminal, and record.
2) Connect the valve voltmeter (oscilloscope) to the Audio
line IN/OUT terminal.
3) Play back the record, and ascertain that the output
waveform level is -8 dBs
±
4 dBs (580 to 1370 mVp-p on
the oscilloscope).
4) If there is any deviation from the specified value, perform
adjustment again as stated in items 1) above, and check
again the self-recording/playback level.
Audio Check
Checking of self-recording/playback
Mode
REC
→
PB
Input signal (tape)
400 Hz, -8 dBs (872 mVp-p)
Measuring terminal Audio IN/OUT
Adjustment address —
Adjustment value
-8 dBs
±
4 dBs (580 to 1370 mVp-p)
Measuring instrument
Valve voltmeter (oscilloscope)
8. Adjustment of chroma emphasis f0
Measuring instrument
Oscilloscope
Mode
VCR STOP
Input signal
Color bar
Measuring point
TL7402
Adjustment address
38
Adjustment level
Minimum chroma component
(1)Input the color bar signal into the video input/output terminal in the VCR STOP mode.
(2)Enter the VCR adjustment mode with an adjustment remote control, and select the address 38.
Select the address, using the FF or REW key, and fix it with the PB key.
(3)Make an adjustment so as to get minimum chroma component on TL7402.
Select the data, using the FF or REW key, and fix it with the PB key.
After the adjustment, press the STOP key, and exit from the adjustment address 38.
9. Adjustment of C recording current
Measuring instrument
Oscilloscope
Mode
VCR STOP
Input signal
Color bar
Measuring point
TL7402
Adjustment address
39
Adjustment level
175
±
10 mVp-p
(1)Input the color bar signal into the video input/output terminal in the VCR STOP mode.
(2)Enter the VCR adjustment mode with an adjustment remote control, and select the address 39.
Select the address, using the FF or REW key, and fix it with the PB key.
(3)Make an adjustment so that the amplitude of red portion gets 175 mVp-p on TL7402.
Select the data, using the FF or REW key, and fix it with the PB key.
After the adjustment, press the STOP key, and exit from the adjustment address 39.
Minimum chroma component
175mVp-p
Red part
Mode
PB
Input signal (tape)
JiGWR5-5CSP
Measuring terminal TL605/AUDIO.OUT
Adjustment address 21
Adjustment value
Clear the waveform
5-1-6. Adjustment of audio circuit
1. Adjustment of filter f0
Measuring instrument
Oscilloscope
1) Set the alignment tape (JiGWR5-5CSP)
2) Using the adjustment remote controller (RRMCG0033TASA),
set the VCR adjustment mode, and set the address “21” with
the operation switch (FF/REWIND key).
3) Play back the standard tape.
4) Using the operation switch (FF/REWIND key), make an
adjustment so that the most clear playback waveform is
obtained on TL605.
5) Press the operation switch (PLAYBACK key) to write the
data.
6) Press the operation switch (STOP key) to exit from the
address “21”.
(The address “21” blinks.)
Содержание ViewCam VL-E610S
Страница 4: ...VL E610S VL E610H VL E660S VL E96E VL E98E 2 2 ...
Страница 57: ...5 19 VL E610S VL E610H VL E660S VL E96E VL E98E ...