5-4
VL-E610S/VL-E610H
VL-E660S/VL-E96E
VL-E98E
Procedural steps
1
Turn up or down the flashing hexadecimal number with the FF or REW key to select the
V ADJ
address of a desired adjustment item. (Initial address: 00H)
Note: The addresses change as follows. 7E 7F 00 01 02
2
Press the PB key to read the data of the selected address.
V ADJ
2C A3
3
Turn up or down the data setting with the FF or REW key. The data display starts flashing.
V ADJ
2C
4
Press the PB key again to write the data setting into the selected address.
V ADJ
2C 72
5
Press the STOP key in the above step
2
or
4
, and the screen returns back to the step
1
.
V ADJ
Display
( : flashing)
When the FF or REW key is held down for 0.3 second or longer, the address selection is repeated in cycles of 100 msec.
The data setting changes by
±
4 by holding the key down for 2 seconds or longer.
5-1-2-3. Battery shut-off voltage adjusting method
1) Supply power to the main unit, using the variable-voltage DC power supply (range of 2.5V to 5V).
2) Set the CAM/OFF/VCR SW to CAM to switch to the camera mode.
3) Load a recordable tape and set the main unit to CAM REC. PAUSE.
4) Set the main unit to TEST mode No. 3, and start recording.
5) Measure voltage between TL901(+) and TL903(GND), and adjust the supply voltage to 3.0V.
6) The adjustment is complete if "BATTERY" is displayed on the monitor screen for a second when the PLAY key of
operation unit is pressed.
7) The adjustment is regarded as proper if the auto shut-off is actuated after the warning is displayed when the TEST mode
is cancelled.
* In case of automatic adjustment of shut-off voltage, adjustment is impossible if voltage is above 3.0V
±
0.2V.
If the adjustment is made at 2.9V or below, the low-voltage operation may become unstable.
•
Types of test modes
Any of the eight test modes can be set up by changing the input voltage at pin (54) of IC703. During any test mode, the
REC Start/Stop commands are not accepted.
1.2k 1.5k 2.2k 3.3k 5.6k 10k 33k
8.2k
5V
54
9
8
7
6
5
4
3
2
Micro
computer
Adjustment tool
Use the SW2 thru SW9 switches on the adjustment tool to select the following test modes.
SW No.
Title
Contents
Sensor on/off
2
Sensors off
All sensors but the cassette controller switch, dew sensor and battery
sensor stay off.
3
Mechanism adjustment mode
1
Automatic SP/LP detection prohibited
All sensors on
2
Different-mode detection prohibited
3
ATF sampling limited to center
4
Automatic battery sensor
Battery sensor’s input voltage put in memory.
adjustment
5
Error display
Past errors appear on the counter display of the viewfinder.
All sensors on
Battery adjustment error display Battery sensor’s adjustment errors are displayed at the right of the
All but sensors
“past errors” area.
on
6
PASS mode
Track shift mode (1/4 shift)
All sensors on
7
Camera adjustment mode
Camera adjustment mode
[VCR
interrupted]
8
VCR adjustment mode
VCR adjustment mode
9
Automatic switching point
Play standard tape and call this mode. Switching point is automatically
adjustment (STOP ADJ)
adjusted.
1
When the battery adjustment mode is selected from the camera adjustment mode with a cassette with the erase
protection tab, the VCR is automatically put in the REC mode.
Содержание ViewCam VL-E610S
Страница 4: ...VL E610S VL E610H VL E660S VL E96E VL E98E 2 2 ...
Страница 57: ...5 19 VL E610S VL E610H VL E660S VL E96E VL E98E ...
Страница 115: ...Ref No Part No Description Code Ref No Part No Description Code 10 26 VL E610S VL E610H VL E660S VL E96E VL E98E ...
Страница 121: ...12 6 VL E610S VL E610H VL E660S VL E96E VL E98E A B C D E F G H 1 2 3 4 5 6 12 2 AC ADAPTER P W B ...
Страница 122: ...12 7 VL E610S VL E610H VL E660S VL E96E VL E98E A B C D E F G H 1 2 3 4 5 6 ...
Страница 128: ......