5-15
VL-E610S/VL-E610H
VL-E660S/VL-E96E
VL-E98E
•
Lens adjustment
Measuring instrument
Subject
More than 50 m away
Tape
—
Test point
None
Adjustment address
1FF
Adjustment level
11, 12, 06, 08
None
1) Set up the auto focus adjustment mode.
(This is unnecessary after the above basic iris adjustment has been made.)
2) Write the adjustment data 11, 12, 06 and 08 one after the other to the address 1FF. The adjustments are as follows.
3) Write FF to the address 1FE to exit the auto focus adjustment mode.
11
Voltage adjustment
12
Optical wide-end adjustment
06
Wide-end focus
∞
position adjustment
08
Tele-end focus
∞
position adjustment
Data
Adjustment
5-2-2-3.
Before starting these adjustments, set up the auto focus adjustment mode.
•
Sync level adjustment
Measuring instrument
Oscilloscope
Subject
Anything
Tape
—
Test point
VIDEO OUT (Terminated in 75
Ω
)
Adjustment address
1F8
Adjustment level
300mVp-p
1) Set up the camera signal line adjustment mode. (Write
00 to the address 1FE)
2) Connect the oscilloscope to the VIDEO-OUT. Adjust the
sync level to300mVp-p.
09
Hall offset
0A
Iris offset
0B
Iris close
Data
Adjustment
Measuring instrument
None
Subject
—
Tape
—
Test point
None
Adjustment address
1FF
Adjustment level
09, 0A, 0B
•
Basic iris adjustment
5-2-2-2. Auto focus adjustment
1) Set up the auto focus adjustment mode. (Write 01 to the address 1FE)
2) Write the adjustment data 09, 0A and 0B one after the other to the address 1FF, the adjustment are as follows.
1H
Video
SYNC
300mVp-p
Содержание ViewCam VL-E610S
Страница 4: ...VL E610S VL E610H VL E660S VL E96E VL E98E 2 2 ...
Страница 57: ...5 19 VL E610S VL E610H VL E660S VL E96E VL E98E ...
Страница 115: ...Ref No Part No Description Code Ref No Part No Description Code 10 26 VL E610S VL E610H VL E660S VL E96E VL E98E ...
Страница 121: ...12 6 VL E610S VL E610H VL E660S VL E96E VL E98E A B C D E F G H 1 2 3 4 5 6 12 2 AC ADAPTER P W B ...
Страница 122: ...12 7 VL E610S VL E610H VL E660S VL E96E VL E98E A B C D E F G H 1 2 3 4 5 6 ...
Страница 128: ......