Initial coordinates (xi, yi)
↔
Touch panel coordinates (xt, yt) conver-
sion
xt = (xi - 4096*x1/x)*(x / (x2-x1))
yt = (yi - 4096*y1/y)*(y / (y2-y1))
Touch panel coordinates (xt, yt)
↔
VGA coordinates (xv, yv) conver-
sion
xv = xt * 640 / 4096
yv = yt * 480 / 4096
•
Coordinates of correction points
Initial coordinates
393, 402
2080, 402
3767, 402
393, 2048
2080, 2048
3767, 2048
393, 3697
2080, 3697
3767, 3697
Touch panel coordinates
100, 100
2048, 100
3996, 100
100, 2048
2048, 2048
3996, 2048
100, 3996
2048, 3996
3996, 3996
VGA coordinates
16, 14
320, 14
624, 14
16, 240
320, 240
624, 240
16, 465
320, 465
624, 465
3. IPL (Initial program Loading) function
1) Introduction
The application software of the UP-3300 written in the flash ROM.
In the following cases, writing procedure of the application software
into the flash ROM is required
•
When the flash ROM is replaced with new one. The service part
flash ROM does not include the application software in it.
•
When IPL writing is required because of change in the software.
*
The service part ofthe main PWB unit includes the flash ROM with
the application software written in it, and there is no need for
writing the application software when replacing the main PWB unit.
2) IPL procedure
There are two ways of IPL procedures.
•
IPL from P-ROM via ER-A7RS
•
IPL from PC via IR ( infrared ) communication (Please refer the
next section)
The detailed descriptions on the above procedures are given below.
3) IPL from P-ROM via ER-A7RS
(1) Install the two master ROMs to the IC socket (IC12 , IC13) on the
ER-A7RS.
Master ROM -1 : VHI27801RAFxx
Master ROM -2 : VHI27801RAGxx
(2) IPL sitch on the ER-A7RS : Set the IPL SW to ON position.
(3) Install the ER-A7RS to the UP-3300. (The UP-3300 power should
be turned OFF.)
(4) Turned on the power of the UP-3300.
(5) The buzzer sounds intermittently during the running of IPL and the
program finishes after the buzzer gives five beeps at short inter-
vals.
(6) Turn OFF the power of the UP-3300.
(7) Remove the ER-A7RS from the UP-3300.
(8) Perform the Master reset .
4. UTL33.EXE (UP-3300 Series Utility tool)
1. Outline
This specification covers the utility program "UTL33.EXE" for UP-
3300 series. The "UTL33.EXE" is a program which runs on the PC
DOS prompt screen, it is connected to the UP-3300 through IR. It has
the following functions: (1) UP-3300 IPL operation; (2) LOGO data
rewrite for built-in printer UP- T80BP; and (3) program rewrite.
2. System requirements
PC and UP-3300 are connected through IR.
Fig 1. Connection between PC and UP-3300
3. Functions
The following three functions become available:
(1) UP-3300 program rewrite (IPL)
The UP-3300 program is updated. S-type files or ER01FD type
data files are used for ROM data.
(2) LOGO data rewrite
The LOGO STAMP data for the UP-T80BP is set.
Black-and-white BMP/PCX data is used and the image size is up
to 576x240 dots.
(3) Program rewrite (IPL)
The UP-T80BP program is updated. S-type files are used for ROM
data.
According to the contents of the file, "UTL33.EXE" automatically
selects the appropriate protocol from the three types described
above. 1
IPL SW
OFF
ON
IC13 ROM2
IC12 ROM1
MASTER
P-ROM -1
MASTER
P-ROM -2
RS-232C
CE-IR4
PC
without IR
UP-3300
PC with IR
UP-3300
1. PC + CE-IR4 system
2. PC only system
3 – 3