CHAPTER 3. CONTROLLING THE MONITOR WITH A PC
PN-T321/T322B
CONTROLLING THE MONITOR WITH A PC
3 – 4
■
FUNCTION (INITIALIZATION/FUNCTIONAL RESTRICTION SETTING) MENU
■
OTHERS
Function
Command
Direction
Parameter
Reply
Control/Response contents
*
1
ALL RESET
RSET
W
0
All reset
---
ADJUSTMENT LOCK
ALCK
WR
0
0
OFF
---
1
1
---
2
2
---
Function
Command
Direction
Parameter
Reply
Control/Response contents
*
1
SCREEN SIZE
(DVI-D, D-SUB)
WIDE
WR
1
1
WIDE
---
2
2
NORMAL
---
3
3
Dot by Dot
---
4
4
ZOOM1
---
5
5
ZOOM2
---
SCREEN SIZE
(HDMI, COMPONENT,
VIDEO)
WIDE
WR
1
1
WIDE
---
2
2
ZOOM1
---
3
3
ZOOM2
---
4
4
NORMAL
---
5
5
Dot by Dot
---
VOLUME
VOLM
WR
0 - 31
0 - 31
---
MUTE
MUTE
WR
0
0
OFF
---
1
1
ON
---
INFORMA-
TION
MODEL
INF1
R
Value
●
SERIAL NO
SRNO
R
Value
●
BRIGHT
VLMP
WR
0 - 31
0 - 31
---
TEMPERATURE SENSOR
DSTA
R
0
Internal temperature normal
●
1
Internal temperature abnormal (Standby mode)
●
2
Internal temperature abnormal (Temperature is
normal now, but it was abnormal during operation.)
●
3
Internal temperature abnormal (Brightness of the
backlight decreases.)
●
4
Temperature sensor abnormal
●
TEMPERATURE ACQUISI-
TION
ERRT
R
Value
Temperature at temperature sensors are returned
in the following forms:
[Sensor 1], [Sensor 2], [Sensor 3]
This monitor does not have sensors 2 and 3. All
return the same value as sensor 1.
Indicates a temperature sensor abnormality when
“126” is returned.
---
CAUSE OF LAST STANDBY
MODE
STCA W
0
Initialization
●
R
0
No detectable error has occurred
●
1
Standby mode by POWER button
●
2
Main power off by the main power switch
●
3
Standby mode by RS-232C
●
4
Waiting mode by No Signal
●
6
Standby mode by abnormal temperature
●