54
E
Function menu
Function
Command Direction
Parameter
Reply
Control/Response contents
*
Monitor Lock
ALCM
WR
0-3
0-3 0: Off, 1: Power Button & Touch, 2: Power Button, 3: Touch
-
Remote Control Lock
ALCR
WR
0-2
0-2 0: Off, 1: All, 2: Except Power & Volume
All Reset
RSET
W
0
0: All Reset
Others
Function
Command Direction
Parameter
Reply
Control/Response contents
*
Bright
VLMP
WR
0-100
0-100
-
Temperature sensor
DSTA
R
0 Internal temperature normal
●
1 Internal temperature abnormal has occurred and the monitor is in standby
state
2 Internal temperature abnormal occurred (To delete the information of
temperature abnormal, turn off the main power.)
3 Internal temperature abnormal has occurred and backlight brightness is
dimmed
4 Temperature sensor abnormal
Temperature acquisition
ERRT
R
Value Returns the temperature at the temperature sensors.
Indicates a temperature sensor abnormality when “126” is returned.
-
Check the resolution
PXCK
R
- Returns current resolution in the form of hhh, vvv.
Sleep (Backlight off)
BOMD
W
0
Move to Sleep (Backlight off) state
1
Returns from Sleep (Backlight off) state
R
0 Sleep (Backlight off) state
1 Normal operation (Backlight on) state