Initialization/Functional Restriction Setting (FUNCTION) menu
Function
Command Direction
Parameter
Reply
Control/Response contents
*
ALL RESET
RSET
W
0-1
0: ALL RESET 1, 1: ALL RESET 2
-
ADJUSTMENT LOCK
ALCK
WR
0
0 OFF
●
W
1-2
1: ON 1, 2: ON 2
○
R
1-2 1: ON 1, 2: ON 2
●
ADJUSTMENT LOCK TARGET
ALTG
WR
0-2
0-2 0: REMOTE CONTROL, 1: MONITOR BUTTONS, 2: BOTH
○
OSD DISPLAY
LOSD
WR
0-2
0-2 0: ON 1, 1: OFF, 2: ON 2
LED
OFLD
WR
0-1
0-1 0: ON, 1: OFF
TEMPERATURE ALERT
TALT
WR
0-2
0-2 0: OFF, 1: OSD & LED, 2: LED
STATUS ALERT
SALT
WR
0-2
0-2 0: OFF, 1: OSD & LED, 2: LED
POWER BUTTON
PBTN
WR
0-1
0-1 0: MONITOR, 1: EXT. CONTROLLER
EXTERNAL CONTROLLER INPUT
PCIP
WR
0-3
0-3 0: D-SUB, 1: DisplayPort, 2: HDMI1, 3: HDMI2
“ERR” when MONITOR is selected for POWER BUTTON.
SIGNAL RESPONSE LEVEL
HDUC
WR
1-200
1-200
APPLICATION
APST
WR
0-1
0-1 0: DISABLE, 1: ENABLE
-
APPLICATION RECOVERY MODE
APRV
W
0
Display the menu for APPLICATION mode recovery
Others
Function
Command Direction
Parameter
Reply
Control/Response contents
*
SIZE (Screen size selection)
WIDE
WR
1-4
1-4 1: WIDE, 2: NORMAL, 3: Dot by Dot, 4: ZOOM
○
INFORMATION Model
INF1
R
Value
●
Serial no.
SRNO
R
Value
Temperature sensor
DSTA
R
0 Internal temperature normal
1 Internal temperature abnormal has occurred and the monitor is in standby
mode
2 Internal temperature abnormal occurred (To delete the information of
temperature abnormal, turn off the main power.)
3 Internal temperature abnormal has occurred and backlight brightness is
dimmed
4 Temperature sensor abnormal
Temperature acquisition
ERRT
R
Value Returns the temperature at the temperature sensors.
Indicates a temperature sensor abnormality when “126” is returned.
○
Cause of last standby mode
STCA
W
0
Initialization
●
R
0 No detectable error has occurred
1 Standby mode by POWER button or MONITOR OFF button
2 Main power off by the main power switch
3 Standby mode by control via RS-232C, LAN, or application
4 Input signal waiting mode by No Signal
6 Standby mode by abnormal temperature
8 Standby mode by SCHEDULE setting
10 Standby mode by HDMI CEC
20 Standby mode by OFF IF NO OPERATION setting
FREEZE
FRMD
WR
0-1
0-1 0: FREEZE release, 1: FREEZE execute
-
LAN setup
FTP ON/OFF select
FCHE
WR
0-1
0-1 0: FTP connection OFF, 1: FTP connection ON
“ERR” when DISABLE is selected for APPLICATION.
○
FTP Username
FUSR
WR
XXXXXXXX
XXXXXXXX 8 characters or less; half-width alphanumeric characters, “-”, and “_”.
(The field cannot be left blank, and spaces cannot be entered.)
“ERR” when DISABLE is selected for APPLICATION.
FTP Password
FPAS
WR
XXXXXXXX
XXXXXXXX 8 characters or less; half-width alphanumeric characters, “-”, and “_”.
(The field cannot be left blank, and spaces cannot be entered.)
“ERR” when DISABLE is selected for APPLICATION.
Controlling the Monitor with a computer (RS-232C)