MX-M753N MX-FR22U 14 – 2
C. Mount the data security kit ROMs to the
control PWB unit.
Remove the ROMs (PROG1 and PROG2) from the control PWB
and replace them with the data security kit ROMs (MFP_PRG1 and
MFP_PRG2).
When mounting the data security kit ROMs, insert them to the
same positions in the same orientations as those before replace-
ment until they click and ensure that the inserted ROMs are locked
into the sockets.
D. Reattach the control PWB and the right cabinet
upper.
•
If the fax box unit is installed, carry out steps 1) and 2) addi-
tionally.
1)
Pass the interface cable through the hole of the sheet metal of
the control PWB, connect it to the control PWB.
2)
Attach the snap band to the sheet metal of the control PWB
unit.
3)
Push the control PWB unit into the main unit.
4)
Secure the unit with the four screws.
•
If the fax box unit is installed, carry out step 5).
5)
Fit the interface cable into the right cabinet upper.
6)
Attach the right cabinet upper to the main unit.
7)
Secure the right cabinet upper with the three screws.
•
Reconnect the cables that have been removed in step B to
the original positions of the control PWB unit.
E. Turn on the main power switch of the main
unit.
1)
Insert the power plug of the main unit to the outlet.
PROG1
PROG2
FAX IMG EXT
PS KANJI
PCL/BARCODE