– 25 –
MD-X8H
8. TEST-PLAY mode
Step 1
Testmode STOP state
[ t s m
e
]
Step 2
Press the CD
MD EDIT button. TEST-PLAY menu
[ T E S T _ P L A Y _ ]
Step 3
Press once the CD STOP button. ADRES setting (Target address initial value is indicated)
[ A D R E S _ 0 0 5 0 ]
Press once the MD PLAY button. While searching, set the search output to "H". To start continuous play,
return it to "L".
Step 4
Continuous playback (pit section) (A C1 error indication)
[s
c
]
Continuous playback (groove section) (A C1 error indication)
[a
c
]
Step 5
Press once the CD STOP button. (A ADIP error indication)
[a
a
]
Continuous playback (groove section)
Step 6
Press once the MD STOP button. TEST-PLAY menu
[ T E S T _ P L A Y _ ]
Step No.
Setting Method
Remarks
Display
• If the MD STOP button is pressed while the TEST-PLAY menu is displayed, TEST mode STOP state is set.
• If the MD PLAY button is pressed while the TEST-PLAY menu is displayed, continuous playback is started from the current pickup position.
• Whenever the CD
MD EDIT button is pressed in the address setting mode, the address changes as follows.
0 0 5 0
→
0 3 C 0
→
0 7 0 0
→
0 8 A 0
→
0 0 5 0
→
…………
• Whenever the CD STOP button is pressed in the address setting mode, the digit which is changed with -
/
+ changes as follows.
0 0 5 0
→
0 0 5 0
→
0 0 5 0
→
0 0 5 0
→
…………
• The digit of address which has been specified with -
/
+ and CD STOP button in the address setting mode is set to +01H/-01H.(0~F)
* If the -
/
+ button is held down, the setting changes continuously with 100 ms cycle.
• If the TRACK EDIT button is pressed in the continuous playback mode, the number of jump lines changes as follows.
1 line
→
10 line
→
400 line
→
1 line
→
…………
* After the number of jump lines is indicated for one second, the address indication is restored.
[
T R _ J U M P ]
• If the -
/
+ button is pressed in the continuous playback mode, the specified number of lines is jumped in the FWD/REV
direction.
* If the -
/
+ button is held down, the setting changes with 100 ms cycle.
• Whenever the CD STOP button is pressed in the continuous playback mode, the indication changes as follows.
* Pit section Continuous playback (SUBQ address indi C1 error indication) remains.
[s
c
]
* Groove section
Continuous playback (ADIP address indi C1 error indication) remains.
[a
c
]
↓
Continuous playback (ADIP address indi ADIP error indication) remains.
[a
a
]
↓
Continuous playback (ADIP address indi C1 error indication) remains.
[a
c
]
↓
•
: Adress,
: Error late,
: Jump lines
………
9. TEST-REC mode
Step 1
Testmode STOP state
[ t s m
e
]
Step 2
Press the CD
MD EDIT button. TEST-REC menu
[ T E S T _ R E C _ _ ]
Step 3
Press once the CD STOP button. ADRES setting (indication of address initial value)
[ a 0 0 5 0 _ p w
]
Step 4
Press once the MD PLAY button. While searching, set the search output to "H". To start continuous play,
[ a
p w
]
return it to "L".
Continuous recording
Step 5
Press once the MD STOP button. TEST-REC menu
[ T E S T _ R E C _ _ ]
Step No.
Setting Method
Remarks
Display
• If the MD STOP button is pressed while the TEST-PLAY menu is displayed, TEST mode STOP state is set.
• If the MD PLAY button is pressed while the TEST-REC menu is displayed, continuous record is started from the current pickup position.
• Whenever the CD
MD EDIT button is pressed in the address setting mode, the address changes as follows.
0 0 5 0
→
0 3 C 0
→
0 7 0 0
→
0 8 A 0
→
0 0 5 0
→
…………
• Whenever the CD STOP button is pressed in the address setting mode, the digit which is changed with -
/
+ changes as follows.
0 0 5 0
→
0 0 5 0
→
0 0 5 0
→
0 0 5 0
→
…………
• The digit of address which has been specified with -
/
+ and CD STOP button in the address setting mode is set to +01H/-01H.(0~F)
* If the -
/
+ button is held down, the setting changes continuously with 100 ms cycle.
• If the VOL UP/VOL DOWN button is pressed in TEST-REC mode and continuous record mode, the laser record power changes.
(Servo gain changes also according to the record power.)
•
: Adress,
: Laser power cord
10. INNER mode
Step 1
Testmode STOP state
[ t s m
e
]
Step 2
Press the TRACK EDIT button.
INNER menu
[ _ _ I N N E R _ _ ]
Step 3
Press once the MD PLAY button. INNER switch position measurement
[s
c
]
(SUBQ address and C1 error are also indicated.)
Step 4
Press once the MD STOP button. INNER menu
[ _ _ I N N E R _ _ ]
Step No.
Setting Method
Remarks
Display
•
: Adress
• Press the MD STOP button while the INNER menu is displayed, to shift to the TEST mode STOP state.
Содержание MD-X7H
Страница 28: ...MD X7H MEMO 18 ...