– 3 –
MD-X5/X5H/X5W/X7/X7H/X8/X8H/X8W/XV300H/XV300X
2. Temperature reference value setting procedure
(to be executed at room temperature within 21 to 29
°
C)
EEPROM (IC1402) writing procedure
1. Procedure to replace EEPROM and to write the initial
value of microcomputer in EEPROM
(See the MD-X8/MD-X8H/MD-X8W service manual, page
28.)
(1) Replace EEPROM.
(2) Refer to the latest EEPROM data list.
(3) Hold down the ENTER button and MD PLAY button, and press
the POWER button to enter the test mode.
When an MD is loaded, "AUT YOBI" will appear.
Press the MD STOP button. When the MD STOP button is pressed,
the version described in step (4) below will be displayed.
(4) Indication of version.
[ t s m
e
]
EEPROM version (c to z)
Microcomputer ROM version
Model code
(5) Press the CD PLAY button 7 times.
[ E E P R O M S E T ]
(6) Perform the operation shown in the "EEPROM setting mode
chart", compare the indication with the EEPROM data list, and
make a setting according to the EEPROM data list, using
MULTI UP button or MULTI DOWN button.
(7) Set the temperature reference value.
(Refer to "Temperature reference setting procedure".)
(8) The setting must conform to the EEPROM data list.
(9) Press the ENTER button to write the data into the EEPROM.
2. Test mode
Test mode setting method
1. Holding down the ENTER button and MD
(PLAY/PAUSE) button, press the POWER button.
(State A is changed to state B .)
2. Insert the playback disc 1 (high reflection disc) or recording disc 2 (low reflection disc). (State C is set.)
Thus, the test mode state is set.
A tsm
e
: TEST MODE
represents version of MD microcomputer.
TEST
STOP state
(When the MD
(STOP) button is ressed in the C state, the indication A
is restored. To restore C again, press the CD
(PLAY/ PAUSE)
button.)
B EJECT
TEST
C AUT YOBI
TEST
Entering the specific mode
Whenever the CD
(PLAY/PAUSE) button is pressed, the mode is changed.
AUTO pre-adjustment
AUTO adjustment
RESULT Pre-adjustment RESULT MANUAL pre-adjustment
EEPROM setting
MANUAL adjustment
MANUAL pre-adjustment (MD-X8W Only)
• Canceling the test mode
When the ENTER button is pressed and held, and then the POWER button is pressed, the TEST mode will be canceled and the
power will be turned off.
(If the ENTER button is pressed, the unit will enter the MD stand-by mode.)
Ambient temperature
correction
+ 12.2
°
C ~ + 15.8
°
C
-0 3
H
+ 15.9
°
C ~ + 19.6
°
C
-0 2
H
+ 19.7
°
C ~ + 23.2
°
C
-0 1
H
+ 23.2
°
C ~ + 26.8
°
C
±
0
H
+ 26.9
°
C ~ + 30.7
°
C
+0 1
H
+ 30.8
°
C ~ + 34.3
°
C
+0 2
H
+ 34.4
°
C ~ + 37.9
°
C
+0 3
H
(1) Test mode stop state.
[ t s m
e
]
(2) Crrect temperature depending on ambient temperature according
to the following table.
An example: When ambient temperature is 22
°
C and meadured
temperature is 73H
Temperature setting = 73 H - 01 H
= 72 H
* When the measured temperature fluctuates between
two values, take lower one (if temperature fluctuates
between 73H and 72H, take 72H).
3) Press the CD PLAY button 7 times.
[ E E P R O M S E T ]
(4) Press the MD PLAY button 1 times.
[ F o c u s ]
(5) Press the CD PLAY button 4 times.
[ T e m p ]
(6) Press once the MD PLAY button.
[ T E M P
]
: Measured temperature,
: Temperature setting
(7) Set temperature to the value determined above, using the
MULTI UP or MULTI DOWN button.
(8) Press the MD STOP button.
[ T e m p ]
: Places to add/change/correct