– 23 –
MD-X8H
Step 18
Press once the CD PLAY button. TCRS comparison level 1 for high reflection
[ T C R S C 1 P _
]
Step 19
Press once the CD PLAY button. Comparison level in case of COUT generation (playback)
[ C O T L V P _
]
Step 20
Press once the CD PLAY button. Comparison level in case of COUT generation (pecord)
[ C O T L V r _
]
Step 21
Press once the CD PLAY button. Auto-move waiting time setting
[ W A I T m_ _ _
]
Step No.
Setting Method
Remarks
Display
d) Slide setting
Step 1
Testmode STOP state
[ t s m
e
]
Step 2
Press the CD PLAY button seven times. EEPROM setting menu
[E E P R O M _ S E T]
Step 3
Press once the MD PLAY button. Focus setting menu
[ _ _ F o c u s _ _ _ ]
Step 4
Press the CD PLAY button three times. Slide setting menu
[ _ _ _ S l e d _ _ _ ]
Step 5
Press once the MD PLAY button. Slide system loop filter gain constant setting
[ S L G _ _ _ _ _
]
Step 6
Press once the CD PLAY button. Slide system loop filter f characteristic constant 2 setting
[ S L 2 _ _ _ _ _
]
Step 7
Press once the CD PLAY button. Slide output limitter setting
[ S L D L I M _ _
]
Step 8
Press once the CD PLAY button. Slide servo output dead zone level setting
[ S L D L E V _ _
]
Step 9
Press once the CD PLAY button. Slide kick pulse level setting (forced move)
[ S L K L V k _ _
]
Step 10
Press once the CD PLAY button. Slide kick pulse level setting (for 10 lines jump auxiliary use)
[ S L K L V t _ _
]
Step 11
Press once the CD PLAY button. Slide kick pulse level setting (move)
[ S L K L V m _ _
]
Step No.
Setting Method
Remarks
Display
•
: Setting volue
• Pressing the REC button causes reversing.
• If the VOL UP button is pressed while the specific setting item is indicated, the setting increases, and the new setting is set in LSI.
• If the VOL DOWN button is pressed while the specific setting item is indicated, the setting decreases, and the new setting is set in LSI.
• If the VOL UP/VOL DOWN button is held down, the setting changes continuously with 100 ms cycle.
•
: Setting volue
• Pressing the REC button causes reversing.
• If the VOL UP button is pressed while the specific setting item is indicated, the setting increases, and the new setting is set in LSI.
• If the VOL DOWN button is pressed while the specific setting item is indicated, the setting decreases, and the new setting is set in LSI.
• If the VOL UP/VOL DOWN button is held down, the setting changes continuously with 100 ms cycle.
Temperature measurement value correction table
Ambient temperature
correction
+ 12.2
°
C ~ + 15.8
°
C
-0 3
H
+ 15.9
°
C ~ + 19.6
°
C
-0 2
H
+ 19.7
°
C ~ + 23.2
°
C
-0 1
H
+ 23.2
°
C ~ + 26.8
°
C
±
0
H
+ 26.9
°
C ~ + 30.7
°
C
+0 1
H
+ 30.8
°
C ~ + 34.3
°
C
+0 2
H
+ 34.4
°
C ~ + 37.9
°
C
+0 3
H
EEPROM record value = Microcomputer measurement value +
Correction
*
EEPROM record value
Value to be measured by the microcomputer at +25
°
C
* Microcomputer measurement value
Value to be measured by the microcomputer at specific
temperature
* Correction value
Correction value for conversion to measurement value at
+25
°
C (see the table shown left)
Note
1. Do without mechanical connection.
2. Do immediately after turning on the power.
Ambient temperature
temperature code
+ 19.6
°
C ~ + 30.7
°
C
0 6
+ 8.7
°
C ~ + 19.6
°
C
0 7
• Temperature code check
The temperature code is read after automatic adjustment. If it is within the range shown below, the adjustment is OK.