Testmode STOP state
[ t s m
e
]
Step 2
Press the CD PLAY button three times. RESULT sub-menu
[ _ R S T _ Y O B I _ ]
Step 3
Press once the MD PLAY button. Indication of measurement value
[ R F G : _
_ _
]
Step 4
Press once the CD PLAY button. Indication of measurement value
[ R C G : _
_ _
]
Step 5
Press once the CD PLAY button. Indication of measurement value
[ R T G : _ _ _ _ _
]
Step 6
Press once the CD PLAY button. Indication of measurement value
[ G T G : _ _ _ _ _
]
Step 7
Press once the CD PLAY button. Indication of measurement value
[ P C H : _ _ _ _
]
Step 8
Press once the CD PLAY button. Indication of measurement value
[ G C H : _ _ _ _
]
Step 9
Press once the CD PLAY button. Indication of measurement value
[ S A G : _ _ _
]
Step 10
Press once the CD PLAY button. Indication of measurement value
[ S B G : _ _ _
]
Step 11
Press once the CD PLAY button. Indication of measurement value
[ S E G : _ _ _
]
Step 12
Press once the CD PLAY button. Indication of measurement value
[ S F G : _ _ _
]
Step 13
Press once the CD PLAY button. Indication of measurement value
[ H A O :
_ _ _]
Step 14
Press once the CD PLAY button. Indication of measurement value
[ H B O :
_ _ _]
Step 15
Press once the CD PLAY button. Indication of measurement value
[ H E O :
_ _ _]
Step 16
Press once the CD PLAY button. Indication of measurement value
[ H F O :
_ _ _]
Step 17
Press once the CD PLAY button. Indication of measurement value
[ L A O :
_ _ _]
Step 18
Press once the CD PLAY button. Indication of measurement value
[ L B O :
_ _ _]
Step 19
Press once the CD PLAY button. Indication of measurement value
[ L E O :
_ _ _]
Step 20
Press once the CD PLAY button. Indication of measurement value
[ L F O :
_ _ _]
Step 21
Press once the CD PLAY button. Indication of measurement value
[ T C O : _
_ _ _]
Step 22
Press once the CD PLAY button. Indication of adjustment error sequence No.
[ Y O B : _
_ _ _]
Step 23
Press once the CD PLAY button. Indication of adjustment status
[ D I F : _
_ _ _]
Step 24
Press once the CD PLAY button. Indication of pre-adjustment not completed (00)/completed (4B)
[ A D J : _
_ _ _]
Step 25
Press once the MD PLAY button. RESULT sub-menu state
[ _ R S T _ Y O B I _ ]
2. AUTO adjustment mode
Step No.
Setting Method
Remarks
Display
Step 1
Testmode STOP state
[ t s m
e
]
Step 2
Press the CD PLAY button two times. AUTO adjustment menu
[ A U T O _ A J S T _ ]
Step 3
Press once the MD PLAY button. The slide moves to the innermost periphery, and automatic
[
: _ _ _ _ _ _ ]
adjustment is started.
• In case of high reflection disc
changes as follows.
PEG
→
HAG
•In case of low reflection disc
changes as follows.
PEG
→
LAG
→
GCG
→
GEG
→
LAG
End of adjustment
If adjustment is OK, Step 4.
If adjustment is NG, Step 7.
Step 4
Adjustment value output
[ _ C O M P L E T E _ ]
Press the MD PLAY button.
STEP 5
Press the MD STOP button.
STEP 2
Step 5
Continuous playback (pit section)
[ s
c
]
Continuous playback (groove section)
[ a
c
]
Step 6
Press the CD STOP button.
Continuous playback (groove section)
[ a
a
]
Press the MD STOP button.
STEP 2 AUTO adjustment menu
Step 7
Adjustment value output
[ C a n ' t _ A D J . ]
Press the MD STOP button.
STEP 2 AUTO adjustment menu
•
: Adjustment name,
: Measurement value,
: Address
3. RESULT sub-mode
Step No.
Setting Method
Remarks
Display
•
: Measurement value,
: Adjustment value,
: Other various informations
• ressing the REC button causes reversing.
• If the VOL UP button is pressed while the set value is indicated, the set value increases, and the new set value is stored in RAM.
• If the VOL DOWN button is pressed while the set value is indicated, the set value reduces, and the new set value is stored in RAM.
• If the VOL UP/VOL DOWN button is held down, the set value changes continuously with 100 ms cycle.
• The digit of increase/decrease by the VOL UP/VOL DOWN button can be shifted with the aid of CD STOP button.
Содержание MD-X7H
Страница 28: ...MD X7H MEMO 18 ...
Страница 29: ...MD X7H MEMO 19 ...