MD-X8H
– 20 –
Step 1
Testmode STOP state
[ t s m
e
]
Step 2
Press the CD PLAY button four times.
RESULT menu
[ _ R E S U L T _ _ _ ]
Step 3
Press once the MD PLAY button. Indication of set value
[ H A G : _ _ _
]
Step 4
Press once the CD PLAY button. Indication of set value
[ H B G : _ _ _
]
Step 5
Press once the CD PLAY button. Indication of set value
[ L A G : _ _ _
]
Step 6
Press once the CD PLAY button. Indication of set value
[ L B G : _ _ _
]
Step 7
Press once the CD PLAY button. Indication of set value
[ P E G : _ _ _
]
Step 8
Press once the CD PLAY button. Indication of set value
[ P F G : _ _ _
]
Step 9
Press once the CD PLAY button. Indication of set value
[ G E G : _ _ _
]
Step 10
Press once the CD PLAY button. Indication of set value
[ G F G : _ _ _
]
Step 11
Press once the CD PLAY button. Indication of set value
[ G C G : _ _ _ _
]
Step 12
Press once the MD STOP button. RESULT menu state
[ _ R E S U L T _ _ _ ]
3. RESULT mode (final adjustment)
Step No.
Setting Method
Remarks
Display
•
: Measurement value
• ressing the REC button causes reversing.
• If the VOL UP button is pressed while the set value is indicated, the set value increases, and the new set value is stored in RAM.
• If the VOL DOWN button is pressed while the set value is indicated, the set value reduces, and the new set value is stored in RAM.
• If the VOL UP/VOL DOWN button is held down, the set value changes continuously with 100 ms cycle.
• The digit of increase/decrease by the VOL UP/VOL DOWN button can be shifted with the aid of CD STOP button.
Step 1
Testmode STOP state
[ t s m
e
]
Step 2
Press the CD PLAY button five times. MANUAL auxiliary adjustment mode
[ _ M N U _ Y O B I _ ]
Step 3
Press once the MD PLAY button. Initial setting
→
Temperature measuring mode
[ T M P : _
_ _ _ ]
Step 4
Press once the CD PLAY button. Offset "0" setting
→
A signal offset tentative measurement
[ H A o :
_ _ _ ]
Step 5
Press once the CD PLAY button. B signal offset tentative measurement
[ H B o :
_ _ _ ]
Step 6
Press once the CD PLAY button. E signal offset tentative measurement
[ H E o :
_ _ _ ]
Step 7
Press once the CD PLAY button. F signal offset tentative measurement
[ H F o :
_ _ _ ]
Step 8
Press once the CD PLAY button. Offset tentative measurement
→
Laser ON
[ L O N : _ _ _ _ _ _ ]
Step 9
Press once the CD PLAY button. Innermost periphery move
→
RF side FG rough adjustment
[ R F g :
_ _
]
Step 10
Press once the CD PLAY button. Focus ATT (A signal) tentative setting
[ S A g :
]
Step 11
Press once the CD PLAY button. Focus ATT (B signal) tentative setting
[ S B g :
]
Step 12
Press once the CD PLAY button. RF side pit section TG adjustment
[ P T G :
_ _
]
Step 13
Press once the CD PLAY button. Pit section COUT level setting
[ P C H :
_
]
Step 14
Press once the CD PLAY button. Outer periphery move
→
RF side groove TG adjustment
[ G T G :
_ _
]
Step 15
Press once the CD PLAY button. Groove section COUT level setting
[ G C H :
_
]
Step 16
Press once the CD PLAY button. RF side TCRS adjustment
[ R C G :
_ _
]
Step 17
Press once the CD PLAY button. Tracking ATT (E signal) setting
[ S E G :
]
Step 18
Press once the CD PLAY button. Tracking ATT (F signal) setting
[ S F G :
]
Step 19
Press once the CD PLAY button. Indication of tracking EFMIO measurement
[ g M I :
_ _ _ ]
Step 20
Press once the CD PLAY button. RF side pit section FG adjustment
[R F G :
_ _
]
Step 21
Press once the CD PLAY button. Focus ATT (A signal) setting
[ S A G :
]
Step 22
Press once the CD PLAY button. Focus ATT (B signal) setting
[ S B G :
]
Step 23
Press once the CD PLAY button. Offset "0" setting
→
A signal offset measurement
[ H A O :
_ _ _ ]
Step 24
Press once the CD PLAY button. B signal offset measurement
[ H B O :
_ _ _ ]
Step 25
Press once the CD PLAY button. E signal offset measurement
[ H E O :
_ _ _ ]
Step 26
Press once the CD PLAY button. F signal offset measurement
[ H F O :
_ _ _ ]
Step 27
Press once the CD PLAY button. TCRS signal offset measurement
[ T C O :
_ _ _ ]
Step 28
Press once the CD PLAY button. A signal offset measurement
[ L A O :
_ _ _ ]
Step 29
Press once the CD PLAY button. B signal offset measurement
[ L B O :
_ _ _ ]
Step 30
Press once the CD PLAY button. E signal offset measurement
[ L E O :
_ _ _ ]
Step 31
Press once the CD PLAY button. F signal offset measurement
[ L F O :
_ _ _ ]
5. MANUAL auxiliary adjustment mode (only low reflection disc)
Step No.
Setting Method
Remarks
Display
•
: Measurement value,
: Set value,
: Account value