6 – 4
GX10i
CONFIDENTIAL
IC005 (LR38821A): TFT DISPLAY CONTROLLER (2/3)
Pin No. Terminal name Input/Output
Description of terminal
57
DB5
Input/Output
Data bus
58
VDD IO
–
Power supply
59
GND
–
Ground
60
VDD CORE
–
Power supply
61
G1
Output
LCD panel G output signal
62
G0
Output
LCD panel G output signal
63
R5
Output
LCD panel R output signal
64
R4
Output
LCD panel R output signal
65
DB6
Input/Output
Data bus
66
DB7
Input/Output
Data bus
67
DB8
Input/Output
Data bus
68
DB9
Input/Output
Data bus
69
R3
Output
LCD panel R output signal
70
R2
Output
LCD panel R output signal
71
R1
Output
LCD panel R output signal
72*
R0
Output
LCD panel R output signal
73*
PSD
Output
Power save signal (for power IC)
74
ECK
Output
Power save signal (for power IC)
75
CV4
Output
Power save signal (for gray scale IC)
76
SE_DI
Input
Data input for four-wire serial IF
77
DB10
Input/Output
Data bus
78
DB11
Input/Output
Data bus
79
DB12
Input/Output
Data bus
80*
BNC
Input
Synchronous/asynchronous bus switch signal
81
GND
–
Ground
82
GSP
Output
Gate start signal
83
GMODE
Output
Gate output switch signal
84
SHD
Output
Power IC ON/OFF control terminal
85
VDD IO
–
Power supply
86
REV1
Output
Polarity reverse control signal
87
SE_DO
Output
Data output for three-wire/four-wire serial IF
88
DB13
Input/Output
Data bus
89
DB14
Input/Output
Data bus
90
DB15
Input/Output
Data bus
91*
NC
–
Not used
92*
NC
–
Not used
93
SPL
Output
Sampling start signal
94
ALW
Output
Write all mode switch signal
95
GCS1
Output
Vertical scan start position setting signal
96
GND
–
Ground
97
REV2
Output
Polarity reverse control signal
98
SE_CK
Output
Control clock for three-wire/four-wire serial IF
99*
SE_LD2
Output
Load signal for four-wire serial IF
100*
NC
–
Not used
101
VDD IO
–
Power supply
102
Dummy2
–
Not used
103
VDD IO
–
Power supply
104*
NC
–
Not used
105
GCK
Output
Gate shift clock
106
GCS2
Output
Vertical scan start position setting signal
107
VDD CORE
–
Power supply
108
PSK
Output
Power save signal (for gray scale IC)
109
SE_LD1
Output
Load signal for three-wire serial IF
110
GND
–
Ground
111*
NC
–
Not used
112
Dummy1
–
Not used
In this unit, the terminal with asterisk mark (*) is (open) terminal which is not connected to the outside.
Содержание GX10i
Страница 36: ...2 32 GX10i CONFIDENTIAL Point Figure 66 Contact points Push Figure 67 Turning power on ...
Страница 84: ...GX10i CONFIDENTIAL MEMO 4 5 ...