![Sharp FO-4500 Скачать руководство пользователя страница 57](http://html.mh-extra.com/html/sharp/fo-4500/fo-4500_service-manual_368214057.webp)
[4] ERROR CODE TABLE
1. Communication error code table
G3 Transmission
Code
Final received signal
Error Condition (Receiver side)
0
Incomplete signal frame
Cannot recognize bit stream after flag
1
NSF, DIS
Cannot recognize DCS signal by echo etc.
Cannot recognize NSS signal (FIF code etc)
2
CFR
Disconnects line during reception (carrier missing etc)
3
FTT
Disconnects line by fall back
4
MCF
Disconnects line during reception of multi page
Cannot recognize NSS, DCS signal in the case of mode change
5
PIP or PIN
The line is hung up without replying to telephone request from the receiving party.
6
RTN or RTP
Cannot recognize NSS, DCS signal after transmit RTN or RTP signal.
7
No signal or DCN
No response in receiver side or DCN signal received* (transmitter side)
8
−
Owing to error in some page the error could not be corrected although the specified number of
error retransmission was at tempted.
11
−
Error occurred after or while reception by the remote (receiving) machine was revealed to be
impossible.
12
−
Error occurred just after fallback.
13
−
Error occurred after a response to retransmission end command was received.
G3 Reception
Code
Final received signal
Error Condition (Receiver side)
0
Incomplete signal frame
Cannot recognize bit stream after flag
1
NSS, DCS
Cannot recognize CFR or FTT signal
Disconnects line during transmission (line error)
2
NSC, DTC
Cannot recognize NSS signal (FIF code etc)
3
EOP
Cannot recognize MCF, PIP, PIN, RTN, RTP signal
4
EOM
Cannot recognize MCF, PIP, PIN, RTN, RTP signal in the case of mode change
5
MPS
The line is hung up without replying to communication request.
6
PR1-Q
Cannot recognize PIP, PIN signal in the case of TALK request
7
No signal or DCN
No response in transmitter (cannot recognize DIS signal) or DCN signal received* (receiver side)
8
−
Error occurred upon completion of reception of all pages.
9
−
Error occurred when mode was changed or Transmission/Reception switching was performed.
10
−
Error occurred during partial page or physical page reception.
11
−
Error occurred after or during inquiry from the remote (transmitting) machine as to whether
reception is possible or not.
12
−
Error occurred during or just after fallback.
13
−
Error occurred after the retransmission end command was received.
2. Service call error massage
1. HEATER ERROR
2. LASER ERROR
3. POLYGON ERROR
4. FAN ERROR
5. PCU COMM, ERROR
FO-4500H
2 – 41
Содержание FO-4500
Страница 16: ...M E M O FO 4500H 1 14 ...
Страница 129: ...Control PWB parts layout Top side 6 11 FO 4500H ...
Страница 130: ...Control PWB parts layout Bottom side 6 12 FO 4500H ...
Страница 133: ...TEL LIU PWB parts layout 6 15 FO 4500H ...
Страница 134: ...6 16 FO 4500H ...
Страница 136: ...Power supply PWB parts layout 6 18 FO 4500H ...
Страница 141: ...M E M O 6 23 FO 4500H ...
Страница 149: ...Scanner unit Fig 6 Optical adjustment tool Fig 7 Fig 8 FO 4500H 8 6 ...