AL-1661CS TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES 10 - 38
5. FAX soft switch setting change quick reference table
Large item
Middle item
Switch content
Key operator
Soft SW No.
Usage
Dialing
Remote machine call
disable
Pause time
None
SW 5-5 – 8
When dialing disable/when error dialing
Dial call signal
User program
SW 48-1, 2
When dialing disable
DTMF-related item
None
SW 51-1 – 5
When dialing disable in PBX (private branch
exchange/Fax service, etc.)
None
SW 53-5 – 8
When dialing disable in PBX (private branch
exchange/Fax service, etc.)
None
SW 39-4 – 8
When dialing disable in PBX (private branch
exchange/Fax service, etc.)
Pulse (10PPS)
None
SW 67-1 – 4
When pulse dialing disable
Signal detection
Busy tone detection
None
SW 7-3
When busy tone detection disable
Busy tone detection
None
SW 51-7, 8
When busy tone error is detected
Dial tone detection
None
SW 7-2
Redial
In case of an error
Resend interval
User program
SW 4-1 – 4
When send errors occur frequently
In case of an error
Number of times of resend User program
SW 40-1 – 8
When busy
Resend interval
User program
SW 4-5 – 8
Whey busy occurs frequently
When busy
Number of times of resend User program
SW 41-1 – 8
Arrival (Call-in) When CI detection
disable
CI detection
None
SW 12-6, 7
No call-in
CI signal OFF detection
time
None
SW 55-1 – 7
No call-in
External
telephone
Setting of an external
telephone connected
Yes/No
None
SW 47-2
When an external telephone is connected
Remote switch
number
Entry of a 2-digit number
User program
SW 2-5 – 8
When remote switch is erroneously detected
Remote switch
setting
Yes/No
User program
SW 8-5
When remote switch is erroneously detected
Communication General
Send level
None
SW 15-4 – 8
When the remote machine cannot receive
signals in a proper level.
JBIG mode
None
SW 17-4, 8
When an error occurs in the JBIG mode
SG3
V34 mode function setup
None
SW 43-1
When SG3 communication error occurs
frequently
V34 symbol rate
None
SW43-4 – 6
When SG3 communication error occurs
frequently
Transmission
G3/SG3
DIS reception check
None
SW 6-8
When an error occurs in phase B
Line equalizer
None
SW 59-5 – 8
Setting is made referring to the distance from the
station when a communication trouble occurs.
SG3
V34 send speed
None
SW 44-1 – 4
When an error occurs in the SG3 communication.
Manual send V34
None
SW 42-8
When an error occurs in the SG3 communication
in FAX service, etc.
G3
Modem send speed
None
SW 16-1 – 4
To specified/unspecified destination
RTN reception error
None
SW 52-5
When judged as “OK” though RTN is received
Reception
G3/SG3
CSI transmission
None
SW 6-3
Maximum reception length None
SW 7-6
When a document of 1m or longer is received
SG3
V34 reception speed
None
SW 44-5 – 8
When fall-down occurs frequently in the SG3
communication
G3
Countermeasure against
echo in reception
None
SW 6-4
When an error occurs in phase B in reception
Modem speed in reception None
SW 16-5, 6
When the line quality is poor and a fall-back or an
error occurs
EYE-Q check only
None
SW 72-1
Change in the detection method of training error
Reception print Paper selection
Automatic reduction print
User program
SW 24-8
When reduction print is not made
Index
Index print setup
User program
SW 32-6
When an index is attached to the reception data
Содержание AL-1661CS