AL-1661CS TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES 10 - 18
46
12
Density adjustment in the
FAX mode (Collective
adjustment)
[Function]
When [START] key is pressed, scan is executed with the entered exposure adjustment value and the
data stored on the FAX side is rewritten into the entered value.
All data of the exposure adjustment values are rewritten into the same value.
For the density adjustment table data, refer to TC46-13 (density adjustment (normal text) in the FAX
mode).
[Operation]
13
FAX mode density
adjustment (normal text)
[Function]
Scan is started with the exposure adjustment value entered with [START] key, and the stored data of
the selected mode on the FAX side is rewritten into the input value.
[Operation]
14
FAX mode density
adjustment (Fine text)
[Function]
When [START] key is pressed, scan is started with the entered exposure adjustment value and the
data of the selected mode on the FAX side is changed to the entered value.
For the density adjustment value table data, refer to TC46-13 (FAX mode density adjustment (normal
text).)
[Operation]
Main
code
Sub
code
Contents
Details of function/operation
1) Initial display
("XX" is the exposure adjustment value of nor-
mal text stored on the FAX side.)
2) Enter a 2-digit value as the exposure adjust-
ment value.
("YY" is the entered exposure adjustment
value.)
3) Scan is started (self print), and the LED of
[START] key is turned off.
4) Print is started (self print).
After completion of printing, returns to “2)” dis-
play.
ADJUST EXP. AUTO
XX
ADJUST EXP. AUTO
YY
ADJUST EXP. AUTO
SCAN YY
ADJUST EXP. AUTO
PRINT YY
Density adjustment value data table
When initializing each data: 50
Mode
Photo
Exposure adjustment value
STD (Normal text)
off
Fine (Fine text)
on
off
Sfine (Super fine)
on
off
1) Initial display
("XX" is the corresponding exposure adjustment
value of normal text mode stored on the FAX
side.)
2) Enter a 2-digit value as the exposure adjust-
ment value with [10KEY].
("YY" is the entered exposure adjustment
value.)
3) Scan is started (self print), and the LED of
[START] key is turned off.
4) Print is started (self print).
After completion of printing, returns to “2)”
display.
ADJUST EXP. STD
XX
ADJUST EXP. STD
YY
ADJUST EXP. STD
SCAN YY
ADJUST EXP. STD
PRINT YY
1) Initial display
("XX" is the corresponding exposure adjustment
value of the fine text mode stored on the FAX
side.)
2) Enter a 2-digit value as the exposure adjust-
ment value with [10KEY].
("YY" is the entered exposure adjustment
value.)
3) Scan start (self print)
4) Print start (self print)
After completion of printing, returns to “2)”
display.
ADJUST EXP. FINE
XX
ADJUST EXP. FINE
YY
ADJUST EXP. FINE
SCAN YY
ADJUST EXP. AUTO
PRINT YY
Содержание AL-1661CS
Страница 200: ...AL 1661CS CIRCUIT DIAGRAM 13 39 6 POWER SUPPLY A 1 2 3 4 5 6 B C D E F G H 1 2 3 4 5 6 POWER SUPPLY 120V 127V ...
Страница 201: ...AL 1661CS CIRCUIT DIAGRAM 13 40 6 7 8 9 10 11 12 6 7 8 9 10 11 12 A B C D E F G H 1 1 ...
Страница 212: ...Memo ...