AL-1661CS TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES 10 - 62
SW35 No.2 Answering telephone connection
Used to set whether the functions of answering telephone connection
mode are enabled or not.
Default: 1 (Yes)
SW35 No.3, No.4 CI delete max. OFF time
Used to set the max. wait time between detection of CI signal pulse
(number of times) and detection of the next CI signal pulse.
If CIK signal pulse is not detected within this time, the number of calls
up to that time is cleared.
Default: 0 0 (5sec)
SW35 No.5–No.8 Answering machine call number setting
Used to set the number of calls to switch to auto receive when answer-
ing telephone is not called in when the receive mode is set to the
answering telephone connection mode.
Setting is made in binary input.
Default: 5 times
SW36 No.1–No.8 CNG/mute detection completion time
Used to set the time for completion of CNG signal/mute detection in the
answering telephone connection mode.
Count is made from the last call signal.
Setting is made in binary input.
Default: 45sec
SW37 No.1–No.4 Silence detection start time
Used to set the time between reception of external telephone and
detection of mute in the answering telephone connection mode.
Default: 5sec
SW37 No.5–No.8 Mute judgment time
Used set the mute judgment time when mute is continued for several
seconds.
Default: 5sec
SW38 No.1, No.2 Protocol monitor
Used to set whether communication protocol result is printed or not
after completion of communication.
Default: 0 0 (Not printed.)
SW38 No.3 Protocol monitor save
Used to set whether the protocol monitor of the last communication is
saved or not. When set to "Saved," the previous protocol monitor can
be printed with SIM 66-21.
Default: 1 (Yes)
SW38 No.4–No.6 Inhibited to use
SW38 No.7 Transfer function
Used to set whether transfer function is enabled or not.
Default: 0 (Inhibit)
SW38 No.8 Inhibited to use
SW39 No.1–No.3 Inhibited to use
SW39 No.4–No.8 DTMF signal send time
Used to set DTMF signal send time.
Setting is made in binary input by the increment of 10ms.
Default: 110ms
SW40 No.1–No.8 Number of times of recall in error
Used to set the number of times of recall when a communication error
occurs.
Setting is made in binary input.
When set to 0, recall is not made.
Default: 1 times
SW41 No.1–No.8 Number of times of recall in busy
Used to set the number of times of recall when busy tone is detected
during transmission.
Setting is made in binary input.
When set to 0, recall is not made.
Default: 2 times
SW42 No.1 Direct send recall
Used to set whether direct send recall wait is allowed or not.
Default: 0 (Allow)
SW42 No.2 FAX receive auto select by CNG detection
Used to set whether FAX receive auto select is enabled or not when
CNG signal is detected with external telephone used.
Default: 1 (Allow)
SW42 No.3 Auto receive select in answering telephone
connection mode
Used to set whether auto receive select function in answering tele-
phone connection mode is enabled or not.
Default: 0 (Inhibit)
SW42 No.4–No.7 Inhibited to use
SW42 No.8 V.34 mode function in manual communication
Used to set whether V.34 mode is enabled or not in manual communi-
cation.
When, however, SW43-1 is set to "0: OFF," V.34 mode is disabled
even tough this switch is set to "1: ON."
Default: 1 (ON)
SW43 No.1 V.34 mode function
Used to set whether V.34 mode is enabled or not as a capacity of own
machine in send/receive.
Default: 1 (ON)
SW43 No.2 Busy tone detection level table
Used to set the busy tone detection level table.
Default: 0 (constant (ROM))
SW43 No.3 V.34 primary channel return mode
Used to set V.34 primary channel return mode.
Default: 1 (PPh)
SW43 No.4–No.6 Symbol speed mask in V.34 receive
Used to set symbol speed mask in V.34 receive.
Default: 1 0 1 (3429)
SW43 No.7 Silence detection level table
Used to set the mute detection level table.
Default: 0 (constant (ROM))
SW43 No.8 Control channel retrain judgment in V.34
reception
Used to set control channel retrain judgment in V.34 reception.
Default: 0 (Judge EQM value)
SW44 No.1–No.4 V.34 primary channel send speed
Used to set send start speed in V.34 send.
Setting is made in binary input of N in "2400 (bps) x N" in the range of
2400bps – 33600bps.
N is set in the range of 0 – 15. When set to 0, 2400bps; when set to 15,
33600bps.
When set to 2400bps, all of SW91 No. 1 – 8 must be set as "Disable".
Default: 33600bps