GENERAL GUIDELINES 

This device is a lighting effect for professional use on stages, in discotheques, theatres, etc. 
This fixture is only allowed to be operated with the max alternating current which stated in the technical 
specifications in the last page of this manual, the device was designed for indoor use only. 
Lighting effects are not designed for permanent operation. Consistent operation breaks may ensure that 
the device will serve you for a long time without defects. Do not shake the device. 
Avoid brute force when installing or operating the device. 
The device shall only be used complete with its protective shield. 
 
While choosing the installation-spot, please make sure that the device is not exposed to extreme heat, 
moisture or dust. The minimum distance between light-output from the projector and the illuminated 
surface must be more than 0.5 meter, Lighting can not be installed where there is combustible. 
 
Always fix the fixture with an appropriate safety cable if you use the quick lock cam in hanging up the 
fixture, please make sure the 4 quick lock fasteners turned in the quick lock holes correctly. 
 
If you use the quick lock cam in hanging up the fixture, please make sure the 4 quick lock fasteners turned 
in the quick lock holes correctly. 
 
Operate the device only after having familiarized with its functions. Do not permit operation by persons not 
qualified for operating the device. Most damages are the result of unprofessional operation. 
 
Please use the original packaging if the device is to be transported. 
For safety reasons, please be aware that all modifications on the device are forbidden. 
 
If this device will be operated in any way different to the one described in this manual, the product may 
suffer damages and the guarantee becomes void. Furthermore, any other operation may lead to 
short-circuit, burns, electric shock, lamp explosion, crash, etc. 
 

INSTALLATION INSTRUCTIONS 

Installing or replacing the lamp 

CAUTION   

 

Only install the lamp with the device unplugged from the mains.

 

 

The lamp has to be replaced when it is damaged or deformed.

 

 
Before replacing the lamp let the lamp cool down, because during operation, the lamp can reach very high 
temperature. 
During the installation of halogen lamps do not touch the glass bulbs bare handed. Always use a cloth to 
handle the lamps during insertion and removal. 
 
Do not install lamps with a higher wattage. They generate higher temperatures than which the device was 
designed for. 
 

Содержание IDEA SPOT 700

Страница 1: ...0 0 1 L E R L A U N A M S R E S U GB I D F E P M O V I N G H E A D S IDEA SPOT 700...

Страница 2: ...enst SGM beh lt sich das Recht vor Verbesserungen an den Produkten vorzunehmen und deshalb empfehlen wir die Bedienungsanleitung dem Produkt stets beizulegen und die Seriennummer auf der letzten Seite...

Страница 3: ...hod via clamp DMX 512 control connection Control Board FUNCTION MODE DMX Address Setting Display the DMX 512 value of each channel Slave Setting Auto Program Music control INFORMATION Time information...

Страница 4: ...solution For smooth and precise resolution Pan 540 630 optional Tilt 265 movement High speed of pan tilt movement speed of pan tilt movement is adjustable Scan position memory auto reposition after un...

Страница 5: ...ective lens 2 LCD Display 3 Mode Esc button 4 Up button 5 Down button 6 Enter button 7 Microphone 8 Wireless DMX antenna 9 Wireless indicator 10 Lamp system 11 Yoke 12 Carrying handle 13 DMX output so...

Страница 6: ...than stated at the end of this manual Make sure the power cord is never crimped or damaged by sharp edges If this would be the case replacement of the cable must be done by an authorized dealer Always...

Страница 7: ...correctly If you use the quick lock cam in hanging up the fixture please make sure the 4 quick lock fasteners turned in the quick lock holes correctly Operate the device only after having familiarize...

Страница 8: ...insert the lamp Gently slide the lamp and its lamp holder back into place and fasten the 4 screws 4 On the access plate there are 3 small screws marked 1 2 and 3 which are used to adjust the lamp hold...

Страница 9: ...ve to be approved by a skilled person once a year The lighting should be put in a relatively broad space Ensure there is no barrier in the range of 50cm around the lighting CAUTION Before taking into...

Страница 10: ...ga holder Pull the safety rope through the holes on the bottom of the base and over the trussing system or a safe fixation spot Insert the end in the carabine and tighten the safety screw DMX 512 cont...

Страница 11: ...channel number from which the fixture starts to listen to the digital control information sent out from the DMX controller The allocation of this starting address is achieved by setting the correct n...

Страница 12: ...less system 1 Connect the transmitter with the DMX controller 2 To make the fixture installed with wireless receiver log in to the transmitter a Initially the indicator on the receiver fixture should...

Страница 13: ...d Clear Lamp Time XXXX Hours XXXX Hours XXXX Hours XXXX Hours XXXX Minute Password XXX ON OFF Password XXX ON OFF Power on running time Fixture running time Fixture Last times clear Lamp running time...

Страница 14: ...Adjust Calibrate Values Password Color wheel Password XXX Color wheel XXX Calbrate and adjust the effects to standard right position Password 050 User Mode Standard Mode Basic Mode Extended Mode User...

Страница 15: ...RMATION Time information Current Time With this function you can display the temporary running time of the device from the last power on The display shows XXXX XXXX stands for the number of hours The...

Страница 16: ...e lamp is full intensity Lamp on off With this function you can switch the lamp on or off via the Control Board Select Lamp on off by turning the encoder Press the encoder the display shows ON or OFF...

Страница 17: ...nel 3 to 57 If you want to set the starting address to 420 set channel 1 to 7 channel 2 to 8 and channel 3 to 164 256 164 420 Wait for approx 20 seconds and the unit will carry out a reset After that...

Страница 18: ...h this function you can adjust the lamp more easily All effects will be canceled the shutter opens and the dimmer intensity will be set to 100 With the individual functions you can focus the light on...

Страница 19: ...ode by turning the encoder Press the Enter button to confirm Select Auto Program by turning the encoder Press the Enter button to confirm Turn the encoder to select Master or Alone The selection Alone...

Страница 20: ...der to select the desired scene numbers You can program a maximum number of 250 scenes Press the Enter button to confirm Press the Mode Esc button in order to return to the main menu Example Program 2...

Страница 21: ...l wheel changing 5 3 5 246 255 no function Color Wheel 0 13 Open white 14 27 Color 1 28 41 Color 2 42 55 Color 3 56 69 Color 4 70 83 Color 5 84 97 Color 6 98 111 Color 7 112 127 Color 8 128 189 Forwar...

Страница 22: ...slow 190 193 No rotation 11 9 15 194 255 Backwards gobo rotation from slow to fast Rotating gobo indexing Fine 1 16 0 255 Fine indexing Rotating gobos cont rotation 2 0 9 Open 10 19 Rot gobo 1 20 29 R...

Страница 23: ...14 12 20 248 255 Macro 16 Focus 15 13 21 0 255 Continuous adjustment from near to far Focus Fine 22 0 255 Continuous adjustment Fine Motorized Zoom 16 14 23 0 255 Zoom adjustment from small to big Mot...

Страница 24: ...to slow 224 254 Pulse closing slow to fast 21 19 31 255 Max Frost Speed Of CMY Colour macro Speed 22 20 32 0 255 Speed Max Min Colour macros CMY and colour wheel 0 7 OFF 8 15 Macro1 16 23 Macro2 24 31...

Страница 25: ...eset 85 87 Scan motor reset 88 90 Colors motor reset 91 93 Gobo motor reset 94 96 Shutter Dimmer motor reset 97 99 Other motor reset 100 119 Internal program 1 secne1 8 of EEPROM 120 139 Internal prog...

Страница 26: ...This message will appear after the reset of the fixture if the magnetic indexing circuit malfunction sensor failed or magnet missing or the stepping motor is defective or its driving IC on the main P...

Страница 27: ...ons and installation spots ceiling suspension trussing 3 Mechanically moved parts must not show any traces of wearing and must not rotate with unbalances 4 The electric power supply cables must not sh...

Страница 28: ......

Страница 29: ......

Страница 30: ...0 0 1 L E R L A U N A M S R E S U 3 7 4 M X MADE IN PRC...

Отзывы: