6
For the installation, you need one Philips MSR GOLD 700 SA/2 DE
Procedure:
1.
Unscrew the 4 screws A, B, C and D on the bottom of the housing, holding the plate where the lamp is
underneath.
2.
Gently pull the socket holder using the knob in the middle.
3.
Carefully insert the lamp into the socket. Please remember there is only one way to insert the lamp.
Gently slide the lamp and its lamp holder back into place and fasten the 4 screws.
4.
On the access plate there are 3 small screws marked 1, 2 and 3.which are used to adjust the lamp
holder in the lamp housing. You can adjust the 3 screws to fine-turn the position of the lamp to get the
maximum light output as shown below.
1
3
2
A
B
C
D
Please remember the lamp is not a hot-restrike type, you must wait for approximately 15 minutes after
having turned off the lamp before you can turn it back on again.
CAUTION
Do not operate this device with open cover.