8.6.3 - MEASURE STATUS
Position the cursor on MEASURE STATUS, press ENTER to confirm
It’s possible to display the gain of the system, with values from 0 to 255.
While displayed, the automatic gain control is not active.
LEFT ARROW to exit
PRIMARY DEVICE
SELF CALIBRATION
MEASURE STATUS
FROZEN GAIN
MAX GAIN TH
PEAK VALUE
START TOTALIZER
ALARM CONFIGURATION
►
G: 00025
MEASURE STATUS
FLOWMETER -
configuration
8.6.4 - FROZEN GAIN
Position the cursor on FROZEN GAIN, press ENTER to confirm.
It’s possible to fix a value of gain (from 1 to 255) and consequently disable the
automatic gain control. Once the value is 000 the automatic gain control restarts.
Use UP ARROW and SCROLL to modify the value.
Press ENTER to confirm. LEFT ARROW to exit without changes.
Default value: 000
PRIMARY DEVICE
SELF CALIBRATION
MEASURE STATUS
FROZEN GAIN
MAX GAIN TH
PEAK VALUE
START TOTALIZER
ALARM CONFIGURATION
►
000
FROZEN GAIN
8.6.5 - MAX GAIN TH
Position the cursor on MAX GAIN TH, press ENTER to confirm.
It’s possible to input a value of gain that it can be reached in normal operation.
If the gain reaches this value, the “GAIN” error code is activated.
Use UP ARROW and SCROLL to modify the value.
Press ENTER to confirm. LEFT ARROW to exit without changes
Default value: 200 (Max gain)
PRIMARY DEVICE
SELF CALIBRATION
MEASURE STATUS
FROZEN GAIN
MAX GAIN TH
PEAK VALUE
START TOTALIZER
ALARM CONFIGURATION
►
200
MAX GAIN TH
8.6.6 - PEAK VALUES
Position the cursor on PEAK VALUES, press ENTER to confirm.
In this sub-menu it’s possible to display or reset the flow rate peak values.
Press SCROLL button to select.
Press ENTER to confirm.
LEFT ARROW to exit
PRIMARY DEVICE
SELF CALIBRATION
MEASURE STATUS
FROZEN GAIN
MAX GAIN TH
PEAK VALUE
START TOTALIZER
ALARM CONFIGURATION
►
DISPLAY VALUE
RESET VALURE
►