Page 22 of 36
www.sgm-lektra.com
FLOWMETER -
configuration
8.6 - FLOW APPL.
Press SCROLL to select the menu and press ENTER to access.
Press LEFT ARROW to exit.
SETUP
DISPLAY
FLOW APPL.
SERVICE
INFO
►
8.6.1 - PRIMARY DEVICE
Position the cursor on primary device, press ENTER to access.
In this sub-menu it’s possible to select and set the primary device available in
the channel.
Press SCROLL button to select the primary device to be setted.
Press ENTER to confirm. LEFT ARROW to exit without changes.
PRIMARY DEVICE
SELF CALIBRATION
MEASURE STATUS
FROZEN GAIN
MAX GAIN TH
PEAK VALUE
START TOTALIZER
ALARM CONFIGURATION
►
WEIRS
FLUMES
TABLE
CUSTOM
►
8.6.1.1 - WEIRS
Position the cursor on WEIRS, press ENTER to access
In this sub-menu it’s possible to select and set the weir kind available in
the channel.
Can be selected: Rectangular Suppressed,
Rectangular Contracted, Trapezoidal and V Notch
Press SCROLL button to select the weir kind to be setted.
Press ENTER to confirm. LEFT ARROW to exit without changes
WEIRS
FLUMES
TABLE
CUSTOM
►
RECT. SUPPRESSED
RECT. CONTRACTED
TRAPEZOIDAL
V NOTCH
►
8.6.1.1.1 - RECT. SUPPRESSED
Position the cursor on RECT. SUPPRESSED (or no constriction rectangular),
press ENTER to access
To set it, simply insert the “L” size
Use UP ARROW and SCROLL to modify the value.
Press ENTER to confirm. LEFT ARROW to exit without changes.
RECT. SUPPRESSED
RECT. CONTRACTED
TRAPEZOIDAL
V NOTCH
►
0000 mm
RECT. SUPPRESSED
L
l/p<1
minimum
p=2 x “i max”
min 250mm
minimum 3 x “i max”
3
3
p
i
45°
NO CONSTRICTION RECTANGULAR WEIR - “Bazin”