Page 5 of 36
www.sgm-lektra.eu
3-FEATURES
FLOWMETER -
features
Housing/sensor material
PC or Al / PP or PVDF wetted part
Mechanical installation
2” GAS M (PP flange DN80 opt.)
Protection degree
IP67/IP68 (Sensor)
Electrical connection
Internal push connectors
Working temperature
-20 ÷ +60°C
Pressure
from 0,5 to 1,5 bar (absolute)
Power supply
12Vdc / 24Vdc
Power consumption
1,5W (4-wires)
Analog output
4...20mA, max 750ohm
Relays output
n°2 3A 230Vac (n.o.)
Digital communication
MUDBUS RTU
Max measure range
max 0.25 ÷ 5m
In case of non perfectly reflecting surfaces, the maximum distance value will be reduced
Blind distance
0,25m
Temperature compensation
digital from -30 to 80°C
Accuracy
±0,2% (of the measured distance) not better than ±3mm.
Resolution
1mm.
Calibration
4 buttons or via MODBUS RTU
Warm-up
1 minutes typical
LCD Display
Plug-in display/keyboard 4 buttons matrix LCD