47
SI 580E DIN SIZE WEIGHING CONTROLER
www.sewhacnm.co.kr
4. CAS Format (22byte) (Refer F-function 37/67-03)
LAMP DISPLAY
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
1
0
1
1
1
1
1
1
1
STABLE
1
Hold
Gross
Weight
TARE
ZERO
Header1
Header2
OL : OVER LOAD
NT : GROSS weight
ST : Stable
GS : Net weight
US : Unstable
6-1-5. Command Mode
Under “Command Mode”, Indicator will recognize the receipt of Order based on
02h(Header) and 03h(END) signal, and transfers ACK/ NAK).
Although wrong value is transmitted, the communication format is not matched, then ACK is
transmitted.