33
SI 580E DIN SIZE WEIGHING CONTROLER
www.sewhacnm.co.kr
◆ Weighing Mode 2 – Limit Mode 2 (F21 – 02 Setting)
– Relay “ON” when weight reaches set value. User’s relay, “A” dry
Relay Output
Relay
Contents
Relay
Contents
OUT 1
current weight ≥ SP1-SP1 freefall(ON)
current weight < SP1-SP1 freefall(OFF)
OUT 2
current weight ≥ SP2-SP2 freefall(ON)
current weight < SP2-SP2 freefall(OFF)
OUT 3
current weight ≥ SP3-SP3 freefall(ON)
current weight < SP3-SP3 freefall(OFF)
OUT 4
current weight ≥ SP4-SP4 freefall(ON)
current weight < SP4-SP4 freefall(OFF)
Free fall setting mode can be set only weighing mode F21 -1, F21-2, F21-6, F21-7, F21-8.
Free fall value < Target value, If you set wrongly,”
err-8
”
shows.
Default Free fall value is “0”.
WEIGHT
SP4-SP4freefall
SP3-SP3freefall
SP2-SP2freefall
SP1-SP1freefall