30
SI 580E DIN SIZE WEIGHING CONTROLER
www.sewhacnm.co.kr
Communication Test (Basic Serial Port)
F83
To test communication condition of basic serial port, connect TX and RX, and enter to F83.
After “COM1” is displayed, PASS or UNPASS will be appeared. (RS-232C Only)
Communication Test (Option Serial Port)
F84
To test communication condition of option serial port, connect TX and RX, and enter to
F83. After “COM2” is displayed, PASS or UNPASS will be appeared. (RS-232C Only)
TIME(H,M,S) Check / Change (24Hours)
F90
Check Current DATE data or you can Change to new date
DATE(Y,M,D) Check / Change
F91
Check Current TIME data or you can Change to new time
SETUP Mode Password Key Setting / Change
F95
Setting the password
1) When “1” displays, input 4
numbers
2) If “2” display, input the 4 numbers once
more. (recheck the password)
Change the password
If “P-W” display, input the
previous saved password .
And set the “FFFF” as New
password.
.
Deactivate Lock setting
If you set password 4 times of
(5555), it is unlocked.
After initialization (F77) the default password is
When setting password you cannot start “SETUP” mode without password, do not
forget your password.
Program & Hard ware Version Check
F98
Check the Program & Hard ware version
Ex) “100 1.04” means H/W : ver.1.00 & S/W : ver.1.04
1----
2----
p-Uj
↑ ↑ ↑ ↑ ↑
1 2 3 4 5