25
SI 580E DIN SIZE WEIGHING CONTROLER
www.sewhacnm.co.kr
■ Relay Output Mode Setting
(refer 5-5. SET-POINT setting)
Weighing Mode Selection
F21
●
1
Limit Mode 1 : SP1 / SP2 / SP3 / Empty Output Setting
2
Limit Mode 2. : SP1 / SP2 / SP3 / SP4 Output Setting “A” dry, User’s relay
3
Packer Mode 1 : Target / SP1 / Finish / Empty Output Setting
4
Packer Mode 2 : Target / SP2 / SP3 / Finish Output Setting
5
Packer Mode 3 : Target / SP2 / SP3 / Empty Output Setting
6
Limit Mode 3. : SP1 / SP2 / SP3 / SP4 Output Setting “B” dry , User’s
relay
7
Accumulating Mode1 : SP1 / SP2 / SP3 / Finish Output setting
8
Accumulating Mode2 : SP1 / SP2 / SP3 / SP4 Output setting
“FINISH Relay” delay time setting (Under F21-03/04 setting)
F22
10
00~99
0.1 sec / Unit Ex)10 : 0.1 x 10 = 1 sec
“Finish Relay” “ON” time setting (Under F21-03/04 setting)
F23
10
00~99
0.1 sec / Unit Ex)10 : 0.1 x 10 = 1 sec
Weight Mode selection
F27
●
0
Absolute weight weighing mode (both plus weight & minus weight)
*When 4-20mA / 0-10V analogue output: Both +/- of weighing data.
1
Positive weight weighing mode (only plus weight)
*When 4-20mA / 0-10V analogue output: Only “+” of weighing data