- 36 -
SI 400 DIGITAL INDICATOR
6-1-5. Modbus Memory Map
-
RO : Read Only
- RW : Read Write
- Each P/N’s set point can’t over max capacity of Indicator.
ex)35.00kg = 3,500 (0xDAC)
- When you input date and time, it should be 6digit.
ex) 1
st
January 2014 = 140101 (0x22345)
15(H) : 50(M) : 17(S) = 155017 (0x25D89)
- Refer the memory register for regarding Lamp, Error, Digital Input, Standard Key,
Special Key
- Modbus Function Codes
'03' (0x03) : Read Holding Registers
'04' (0x04) : Read Input Registers
'06' (0x06) : Write Single Registers
'16' (0x10) : Write Multiple Registers
- CRC Check Method is CRC-16.
Add-
ress
Leng
-th
Fea-
ture
Description
1
2
RO Capacity
3
2
RO Real weight
5
2
RO Analog raw data
7
2
RO Span value
9
1
RO Division
10
1
RO Decimal
11
2
RO Current weight
13
2
RO Tare weight
15
2
RO Estimated weight
17
2
RO Digital input
19
2
RO Lamp
21
2
RO Error
25
2
RO
Current Product No
Sub times
27
2
RO
Current Product No
Sub weight
33
2
RO
Current P/N Grand-
total count
35
2
RO
Current P/N Grand-
total weight
437
2
RW Date
439
2
RW Time
441
1
RW Basic key
444
1
RW Current Product No.