- 10 -
SI 400 DIGITAL INDICATOR
3-4. Real Panel
(1) AC Power input terminal
(2) External input terminal: User selectable 6EA (Function 233~238)
(3) Serial Interface terminal
Terminal
RxD
TxD
GND
C/L
C/L
RS – 232
Rx
Tx
GND
C/L
C/L
(4) Loadcell Input terminal
Terminal
EXC+
EXC-
SIG+
SIG-
SHLD
Load cell
EXC+
EXC-
SIG+
SIG-
SHEILD
(5) Analogue Output terminal
Terminal
-
+
4~20mA
(-)
(+)
Option
0~10V
(-)
(+)
Option
(6) Option serial interface terminal
Terminal
1
2
3
4
RS – 232C
GND
GND
Rx
Tx
Option
RS – 422
TxD-
TxD+
RxD-
RxD+
Option
RS - 485
Unused
Unused
D-
D+
Option
Please check the Comm. and other specification in the label, attached on the cover
plate first, and make connection according to that information.
(2)External Input
(3)SERIAL I/F
(4)LOAD CELL
(1)POWER
(5)AnalogOutput
(6)Option SERIAL I/F