- 25 -
SI 400 DIGITAL INDICATOR
306
Date transference under stream mode
00
00:Countinuously
01:Single time on every steady state
02:At the first steady point
03:When input print key
307
Modbus Transmit Data MSB/LSB
location
00
00:Standard, 01:Change
308
Parity / Stop bit (Option Port)
00
00: Data bit8, Stop bit1, Parity bit Non
01: Data bit8, Stop bit1, Parity bit Odd
02: Data bit8, Stop bit1, Parity bit Even
03: Data bit7, Stop bit1, Parity bit Non
04: Data bit7, Stop bit, Parity bit Even
309
Serial Communication Speed
(Option Port)
02
00: 2,400bps 01: 4,800bps 02: 9,600bps 03:
14,400bps 04: 19,200bps
05: 28,800bps 06: 38,400bps
07: 57,600bps 08: 76,800bps
09: 1115,200bps
310
Data transmission mode (Option Port)
02
00:Simplex / Stream Mode
01:Duplex / Command Mode
02:Print Mode
311
“Check-Sum” detection selection under
command mode (Option Port)
00
00: Disuse, 01: Use
312
Data Format under Stream Mode
(Option Port)
00
00 : Format 1 (19byte)
01 : Format 2 (22byte)
02 : Format 3 (17byte)
03 : Format 4 (22byte)
05 : Format 5 (15byte)
313
Date transference under stream mode
(Option Port)
00
00 : Continuously
01 : Single time on every steady state
02 : At the first steady point
03 : When input print key
04 :
When input print key
316
Ethernet
transference Method
selection
(Option Port)
00
00 :
Simplex Mode / Stream Mode
01 :
Duplex Mode / Command Mode
02 : MODBUS (RTU)
317
Ethernet
Command mode “Check
Sum” detection selection
(Option
Port)
00
00 : Not Used
01 : Used