- 27 -
SI 400 DIGITAL INDICATOR
414
Gate Way Setting 2
-
0~255
415
Gate Way Setting 3
-
0~255
416
Gate Way Setting 4
-
0~255
417
Port Setting
-
0~65000
◆
Weighing Data Saving time point and print
Weighing Data Save Method
(F-function 103)
Print input
(Key,
Communication,
External input)
Printing out data
Saving Data
00 Manual
○
Current weight
Current weight
Ⅹ
Ⅹ
Ⅹ
01 Auto: At every steady states
○
Recent stable weight
Ⅹ
Ⅹ
Steady weight
Steady weight
02 Auto: At the first steady states
○
Recent stable weight
Ⅹ
Ⅹ
Steady weight
Steady weight
04 Manual& Auto: At every steady states
○
Current weight
Current weight
Ⅹ
Steady weight
Steady weight
05 Manual& Auto: At the first steady states
○
Current weight
Current weight
Ⅹ
Steady weight
Steady weight
5-3-4. Hidden Function
How to enter Hidden function setting mode : Press
Key during 4sec and input your
password. Default password is
(0400). Press
key after input
your password.
Serial Number Check
HF01
Check your device’s serial number
Operation time check
HF02
Check how long hours it has been operated. (Power ON) Unit : 1hour
S/W Version Check
HF03
Check the currently applied program version
H/W Version Check
HF04
Check the currently applied hardware version