5
Overview of parameters
Startup
P45x parameter group 45. PI controller reference signal
P450 PI actual value reference
0.0 – 100.0%
P451 signal = "1"
1 / PI actual value > PI ref
P5xx parameter group 5.. Monitoring functions
P50x parameter group 50. Speed monitoring 1 / 2
P500 / P502 speed monitoring 1 / 2
Off (up to firmware status x.10)
On / motor / regenerative
P501 / P503 deceleration time 1 / 2
0 – 1 – 10 s
P54x parameter group 54. Gear unit/motor monitoring
P540 drive vibration response/warning
Display error
P541 drive vibration response/fault
Rapid stop/warning
P542 response to oil aging/warning
Display error
P543 response to oil aging/fault
Display error
P544 oil aging/overtemperature
Display error
P545 oil aging/ready
Display error
P549 response to brake wear
Display error
P56x parameter group 56. Ex-e motor current limitation
P560 Ex-e motor current limitation
On / off
P561 frequency A
0 – 5 – 60 Hz
P562 Current limit A
0 – 50 – 150%
P563 frequency B
0 – 10 – 104 Hz
P564 current limit B
0 – 80 – 200%
P565 frequency C
0 – 25 – 104 Hz
566 current limit C
0 – 100 – 200%
P567 frequency D
0 – 50 – 104 Hz
P568 current limit D
0 – 100 – 200%
P57x parameter group 57. Motor protection
P570 frequency E
0 – 87 – 104 Hz
P571 current limit E
0 – 100 – 200%
P6xx parameter group 6.. Terminal assignment
P60x parameter group 60. Digital inputs
P601 digital input DI02
CCW/stop
P602 digital input DI03
Enable
P603 digital input DI04
n11/n21
P604 digital input DI05
n12/n22
P608 digital input DI050
Fault reset
P61x parameter group 61. Digital inputs of option
P610 digital input DI10
No function
P611 digital input DI11
No function
P612 digital input DI12
No function
P613 digital input DI13
No function
P614 digital input DI14
No function
P615 digital input DI15
No function
P616 digital input DI16
No function
P62x parameter group 62. Digital outputs of basic unit
P620 digital output DO01
/FAULT
P621 digital output DO02
BRAKE RELEASED
P622 digital output DO03
READY
P63x parameter group 63. Digital outputs DO