Operating Instructions – MOVITRAC® B
121
5
Overview of parameters
Startup
P136 / P146 stop ramp t13 / t23 up = down
0 – 2 – 20 s
P139 / P149 ramp monitoring 1 / 2
Yes / nein
P15x parameter group 15. Motor potentiometer function
P150 ramp t3 up = down
0.2 – 20 – 50 s
P152 save last setpoint
Off
P16x / P17x parameter group 16. / 17. Fixed setpoints 1 / 2
P160 / P170 internal setpoint n11/n21
–5000 – 150 – 5000 1/min
P161 / P171 internal setpoint n12 / n22
–5000 – 750 – 5000 1/min
P162 / P172 internal setpoint n13/n23
–5000 – 1500 – 5000 1/min
P163 / P173 n11 / n21 PI controller
0 – 3 – 100%
P164 / P174 n12 / n22 PI controller
0 – 15 – 100%.
P165 / P175 n13 / n23 PI controller
0 – 30 – 100%
P2xx parameter group 2.. Controller parameters
P25x parameter group 25. PI controller
P250 PI controller
0 / off
P251 P-gain
0 – 1 – 64
P252 I-component
0 – 1 – 2000 s
P3xx parameter group 3.. Motor parameters
P30x / 31x parameter group 30. / 31. Limits 1 / 2
P300/P310 start/stop speed 1/2
0 – 150 1/min
P301 / P311 minimum speed 1 / 2
0 – 15 – 5500 1/min
P302 / P312 maximum speed 1 / 2
0 – 1500 – 5500 1/min
P303 / P313 current limit 1 / 2
0 – 150% I
N
P32x / P33x parameter group 32. / 33. Motor adjustment 1 / 2
P320 / P330 automatic adjustment 1/2
On
P321 / P331 boost 1 / 2
0 – 100%
P322/P332 IxR adjustment 1/2
0 – 100%
P323/P333 premagnetization time 1/2
0 – 2 s
P324/P334 slip compensation 1/2
0 – 500 1/min
P34x parameter group 34. Motor protection
P340 / P342 motor protection 1 / 2
OFF / ON ASYNCHRONOUS
P341/P343 type of cooling 1/2
FAN COOLED
P345 / P346 IN-UL monitoring
0.1 – 500 A
P4xx parameter group 4.. Reference messages
P40x parameter group 40. Speed reference signal
P400 speed reference value
0 – 750 – 5000 1/min
P401 hysteresis
0 – 100 – 500 1/min
P402 deceleration time
0 – 1 – 9 s
P403 signal = "1"
0 / n < n
ref
P43x parameter group 43. Current reference signal
P430 current reference value
0 – 100 – 150% I
N
P431 hysteresis
0 – 5 – 30% I
N
P432 delay time
0 – 1 – 9 s
P433 signal = "1"
0 / I < I
ref
P44x parameter group 44. Imax signal
P440 hysteresis
0 – 5 – 50% I
N
P441 delay time
0 – 1 – 9 s
P442 signal = "1"
0 / I = I
max
00