Factors that can shorten the inspection and maintenance intervals include:
•
Number of real emergency stop braking operations
•
Particularly high number of cycles with high motor acceleration
•
Especially high cyclic duration factor at high speed
•
Changing direction of rotation (reversing operation)
•
Vertical mounting positions and pivoted mounting positions
•
High mass moments of inertia due to the motion of the drive, e.g. in mobile drives
or drives subject to high impact and vibration load
•
Application-related generative torques or torsional vibrations
•
External environmental factors, such as moisture, high degree of UV exposure,
low ambient temperatures, etc.
Unit / part of
unit
Time interval
What to do?
Servomotor
•
Every 10 000 operating hours
1)
Inspect the servomotor:
•
Check ball bearing.
BH.. brake
•
depending on loading circumstances,
at the latest
after 3 months
Inspect the brake:
•
Connect the brake to a regulated power
supply unit. Determine the opening
voltage (clicking of the brake) by in-
creasing the voltage from 10 to 24 V.
•
Check the braking torque. Loop in the
brake, see chapter "Startup after stor-
age".
•
Contact SEW‑EURODRIVE Service
when maintenance is required