4
Mechanical installation
Installation tolerances
Operating Instructions – Stainless Steel Servo Gearmotors
22
•
Motor shaft ends and flange surfaces must be thoroughly cleaned of anti-corrosion
agents, contamination or similar. Use a commercially available solvent. Make sure
that the solvent does not come into contact with the bearing or sealing rings as it
may damage the material.
•
Make sure the customer's counter-bearing is unobstructed and can move freely.
•
Provide for sufficient clearance around the motor to allow for adequate cooling.
•
Make sure that it does not reuse the exhaust air warmed by other devices.
•
Balance components for subsequent mounting on the shaft only with a half key
(motor shafts are balanced with a half key).
•
Turn the rotor by hand and listen for unusual grinding noise.
•
Check the direction of rotation in decoupled state.
4.2.1
Installation in damp locations or in the open
•
Try to arrange the motor and encoder connection so that the connector cables do
not point upwards.
•
Clean the sealing surfaces of the connector (motor or encoder connection) before
reassembly.
•
Replace any brittle seals.
•
Check that the degree of protection is maintained.
•
If necessary, attach covers (protection canopy).
4.3
Installation tolerances
Shaft end
Flanges
Diameter tolerance according to
EN 50347
•
ISO k5
•
Center hole according to DIN 332,
shape DR
Centering shoulder tolerance according
to EN 50347
•
ISO j6
26880490/EN – 05/2022