6
Startup
Startup after storage
Operating Instructions – Stainless Steel Servo Gearmotors
35
INFORMATION
If the insulation resistance is too low, the motor has absorbed moisture.
SEW‑EURODRIVE recommends to send the motor back to SEW‑EURODRIVE to-
gether with a description of the fault.
The following figure shows the minimum insulation resistance depending on the tem-
perature.
100
10
1
0,1
0
20
40
60
80
T/°C
R/MΩ
[1]
9007202147046283
[1]
Resistance/temperature point (RT point)
26880490/EN – 05/2022