Safety notes
Warning notes on the motor
Operating Instructions – Stainless Steel Servo Gearmotors
12
2.8.4
Electrical connection
The connection must be a permanently secure electrical connection (no protruding
wire ends). Use the corresponding cable end equipment. Establish a safe PE connec-
tion. When the motor is connected, the distances to non-insulated and live parts must
not be shorter than the minimum values according to IEC 60664 and national regula-
tions. With low voltage, the distances should be no shorter than the following values,
in compliance with IEC 60664:
Nominal voltage V
N
Distance
≤ 500 V
3 mm
≤ 690 V
5.5 mm
2.9
Warning notes on the motor
Observe the warning safety notes specified on the motor. The following safety notes
can be found on the motor:
Safety note
Meaning
Warning of hot surfaces.
The attached safety notes can become dirty or illegible over time. Always make sure
that safety and operating notes are legible. Replace damaged labels.