![SEW-Eurodrive MOVIPRO ADC Скачать руководство пользователя страница 52](http://html.mh-extra.com/html/sew-eurodrive/movipro-adc/movipro-adc_operating-instructions-manual_1250122052.webp)
6
Mechanical installation
Waste heat
Operating Instructions – MOVIPRO
®
ADC
52
6.4
Waste heat
Ensure that the cooling fins can dissipate waste heat into the environment by free con-
vection.
Observe the following notes to ensure optimum heat convection:
•
Use SEW‑EURODRIVE mounting systems or suitable spacers, e.g.:
– Spacers
– Profiles
– Square pipes
– Mounting plates
– T-beams
– Rails
•
Ensure that the cooling fins are not located in a closed hollow space.
•
It is essential that a minimum distance of 15 mm between the highest cooling fin
and the next surface, e.g. mounting plate, is maintained.
•
Avoid heat sources in the immediate proximity of the device.
6.5
Assembly
Use one of the following mechanical mounting options:
•
Mounting with mounting brackets
•
Mount using the through bores
6.5.1
Mounting with mounting brackets
CAUTION
Risk of injury due to protruding parts.
Minor injuries.
•
Wear suitable protective gloves.
NOTICE
External force too high.
Damage to the thread or the screw.
•
Do not exceed the maximum tightening torque of 3.2 Nm.
Required material
•
"Large bracket mounting set" accessories (part number 12708305):
– 4 mounting brackets
– 8 studs M5 × 8
•
Holding fixture, e.g. square pipe with an edge length ≤ 32 mm
•
Suitable mounting and safety elements
– For mounting at device: Studs M5 × 8 (included in mounting kit), M8 × 30
22749055/EN – 04/2016