193
Code Meaning
Response
(P)
Sub-
code
Meaning
Possible cause
Measure
122
Absolute
encoder
Immediate
stop
513
EnDat encoder:
Plausibility check
514
EnDat encoder:
internal encoder
error
Replace the encoder.
515
516
544
576
EnDat encoder:
internal encoder
warning
Check the encoder
parameterization.
122
Absolute
encoder
Immediate
stop
768
CANopen en-
coder: PDO
timeout
No PDO data from
CANopen encoder
•
Check the inter-
face.
•
Check the config-
uration.
769
CANopen en-
coder: Encoder
signals program-
mable error
Check the encoder
parameterization.
770
CANopen en-
coder: Change of
position
122
Absolute
encoder
Immediate
stop
771
CANopen en-
coder: Emer-
gency signal
Check the encoder.
772
CANopen en-
coder: internal
encoder error
Replace the encoder.
773
774
122
Absolute
encoder
Immediate
stop
16385 HIPERFACE
®
distance encoder:
Plausibility check
16386 HIPERFACE
®
distance encoder:
Unknown en-
coder type
122
Absolute
encoder
Immediate
stop
16387 HIPERFACE
®
distance encoder:
Corrupt encoder
nameplate data
16417 HIPERFACE
®
distance encoder:
Analog voltages
not within toler-
ance