Manual reset
A manual reset can be performed via one of the following options:
•
Disconnect the voltage supply. Adhere to a minimum switch-off time of 1 minute.
Switch the supply voltage back on.
•
Perform a reset via the power section parameters.
•
Perform a reset via the process data interface.
Auto reset
The device has an auto reset function. Due to this function the device automatically
performs up to 5 resets.
To configure the device auto reset proceed as follows:
1. Connect device with your PC or laptop via the Ethernet service interface.
2. Open
MOVITOOLS
®
MotionStudio. Perform a device scan by clicking the [San]
button.
3. Right-click on the device power section.
4. In the context menu click on the buttons [Startup] > [Parameter tree].
5. Choose [8.. Device functions] > [84. Reset behavior] in the parameter tree.
6. In the drop-down list set parameter
P841
to "On".
7. Set parameter
P842
to a time span in seconds. In case an error occurs, the device
will then perform an auto reset after that set time.
A maximum of 5 auto resets are possible during an auto reset phase. If the auto reset
function has reset 5 errors, no further auto reset is possible. In this case you have to
reset manually. For more information, refer to chapter "Manual reset" (→
10.5
Electronics Service by SEW‑EURODRIVE
If you are unable to rectify a fault, contact
SEW‑EURODRIVE
Service. For the ad-
dresses, refer to www.sew‑eurodrive.com.
When contacting the
SEW‑EURODRIVE
Service, always specify the following inform-
ation so that our service personnel can assist you more effectively:
•
Information on the device type on the nameplate (e.g. type designation, serial
number, part number, product key, purchase order number)
•
Brief description of the application
•
Error message on the status display
•
Nature of the fault
•
Accompanying circumstances
•
Unusual events preceding the problem
22749055/EN – 04/2016