![SEW-Eurodrive MOVIPRO ADC Скачать руководство пользователя страница 198](http://html.mh-extra.com/html/sew-eurodrive/movipro-adc/movipro-adc_operating-instructions-manual_1250122198.webp)
10
Service
Device replacement
Operating Instructions – MOVIPRO
®
ADC
198
7. Install the new device in the plant. Connect it to the supply system.
8. Switch on the new device.
INFORMATION
The device performs several initialization steps. Do not switch off the device during
this time.
The data backup of the communication and control unit is restored.
7-segment display:
Status LED S2: flashing green/orange
This can take several minutes.
Do not switch off the device during this process!
The data of the communication and control unit have been restored. Carry out a DC 24 V
reset by switching the device off and back on again.
7-segment display:
Status LED S2: flashing green
Status LED S3: is lit green
Boot sequence is active.
7-segment display:
–
The data backup of the power section is restored.
7-segment display:
Status LED S2: flashing green
Status LED S3: is lit green
7-segment display:
Status LED S2: flashing green
Status LED S3: is lit green
The data backup has been completely restored.
3 seconds
> 5 minutes
Incorrect version of
bootloader software
Chapter
"SD memory card
as spare part"
27021599717141259
•
The parameters saved on the SD memory card are now available again. If a differ-
ent parameter set is needed for the new device, change the parameter set now.
Back up the changed data on the SD memory card again after startup.
•