4
Mechanical Installation
MOVIFIT® Hygienicplus version
30
Operating Instructions – MOVIFIT
®
-FC
4.6
MOVIFIT
®
Hygienic
plus
version
4.6.1
Installation notes
Observe the following additional notes when installing the Hygienic
plus
version of
MOVIFIT
®
-FC:
• Make sure to prevent moisture and dirt from entering the unit during the installation.
• After electrical installation and during assembly, make sure all gaskets and sealing
surfaces are clean and undamaged.
• Check the state of the profile gasket in the EBOX when performing maintenance
work. If damaged: Consult SEW-EURODRIVE.
• The IP69K degree of protection is achieved only if the plastic screw plugs delivered
as standard are replaced by suitable IP69K screw connections (see page 145) and
the approved mounting position is observed (see page 20).
• Make sure to install the cable with a drip loop; see the following figure:
TIPS
SEW-EURODRIVE guarantees that the Hygienic
plus
special surface treatment is free
from faults when delivered. Report any damage that has occurred during transport
immediately.
Although the special surface treatment has a high impact resistance, the housing
surfaces are to be handled with care. The corrosion protection can be affected by
damage to the special surface treatment resulting from improper handling during trans-
port, installation, operation, cleaning, etc. SEW-EURODRIVE is not liable for such
damage.
512769547
DI01
DI02
DI03
DI00
DI05
DI06
DI07
DI04
DI09
DI10
DI03
DI08
DI13/D
O01
DI14/D
O02
Ethern
et1
Ethern
et2
Ethern
et3
COM
RUN
2
NET3
24V
3
DI12/D
O00
SNI-
Mas
ter
Содержание MOVIFIT-FC