6
Startup
Startup MOVIFIT® frequency inverter
106
Operating Instructions – MOVIFIT
®
-FC
DIP switch S10/5
Lower motor power rating
• When activated, this DIP switch enables MOVIFIT
®
to be assigned to a motor with a
lower power rating. The rated unit power is not affected.
• When a motor with a lower power rating is used, the overload capacity of the drive
can be increased because, from the perspective of the motor, MOVIFIT
®
is one
power rating too high. A higher current can be provided briefly, leading to higher
torque ratings.
• The aim of switch S10/5 is to achieve short-term utilization of the motor's peak
torque. The unit's current level remains the same regardless of the switch setting.
Blocking protection for the motor is adjusted depending on the switch position.
• When DIP switch S10/5 is activated, the motor cannot be operated with stall protec-
tion.
DT / DV
V
=
AC 3 x 400 V, 50 Hz
MOVIFIT
®
Assigned DT/DV motor and brake
1)
S10/5 = OFF
S10/5 = ON
Õ
connection
Ö
connection
Õ
connection
Ö
connection
Motor
Brake
Motor
Brake
Motor
Brake
Motor
Brake
MTF..003..00
DT71D4
BMG05
DR63L4
BR03
DR63L4
BR03
-
-
MTF..005..00
DT80K4
BMG1
DT71D4
BMG05
DT71D4
BMG05
DR63L4
BR03
MTF..007..00
DT80N4
BMG1
DT80K4
BMG1
DT80K4
BMG1
DT71D4
BMG05
MTF..011..00
DT90S4
BMG2
DT80N4
BMG1
DT80N4
BMG1
DT80K4
BMG1
MTF..015..00
DT90L4
BMG2
DT90S4
BMG2
DT90S4
BMG2
DT80N4
BMG1
MTF..022..00
DV100M4
BMG4
DT90L4
BMG2
DT90L4
BMG2
DT90S4
BMG2
MTF..030..00
DV100L4
BMG4
DV100M4
BMG4
DV100M4
BMG4
DT90L4
BMG2
MTF..040..00
DV112M4
BMG8
DV100L4
BMG4
DV100L4
BMG4
DV100M4
BMG4
DAS
V
=
AC 3 x 400 V, 50 Hz
MOVIFIT
®
Assigned DAS motor and brake
2)
S10/5 = OFF
S10/5 = ON
Õ
connection
Ö
connection
Õ
connection
Ö
connection
Motor
Brake
Motor
Brake
Motor
Brake
Motor
Brake
MTF..003..01
DAS80N4
BR1
DAS80K4
BR1
DAS80K4
BR1
-
-
MTF..005..01
DAS90S4
BR2
DAS80N4
BR1
DAS80N4
BR1
DAS80K4
BR1
MTF..007..01
DAS90L4
BR2
DAS90S4
BR2
DAS90S4
BR2
DAS80N4
BR1
MTF..011..01
DAS100M4
BR2
DAS90L4
BR2
DAS90L4
BR2
DAS90S4
BR2
MTF..015..01
DAS100L4
BR2
DAS100M4
BR2
DAS100M4
BR2
DAS90L4
BR2
MTF..022..01
-
-
DAS100L4
BR2
DAS100L4
BR2
DAS100M4
BR2
MTF..030..01
-
-
-
-
-
-
DAS100L4
BR2
MTF..040..01
-
-
-
-
-
-
-
-
1)
Possible brake voltages: 110 V, 230 V, 400 V
2)
Possible brake voltages: BR1: 230 V, BR2: 230 V and 400 V
0
0
I