4
Mechanical Installation
Central opening/closing mechanism
26
Operating Instructions – MOVIFIT
®
-FC
4.4
Central opening/closing mechanism
4.4.1
Opening the unit
A socket wrench (SW8) is required for the central retaining screw.
1. Loosen the central retaining screw and continue to turn it counterclockwise until the
EBOX stops moving further up.
2. Remove the EBOX from the ABOX by lifting it upwards. Do not twist the EBOX.
WARNING
The surface temperature of the MOVIFIT
®
-FC can be very high during operation.
Danger of burns
• Do not touch MOVIFIT
®
-FC until it has cooled down sufficiently.
NOTICE
If the torque is too high, the central opening/closing mechanism can be destroyed.
• Tighten the retaining screw up to the stop using a tightening torque of 7 Nm
(60 lb.in).
The degree of protection specified in the technical data only applies when a unit is
mounted correctly. When the EBOX is removed from the ABOX, moisture, dust, or
foreign particles can damage the MOVIFIT
®
.
• Protect the ABOX and EBOX when the unit is open.
813086859
813353099
EBOX
ABOX
EBOX
ABOX
90°