62
MOVIDRIVE
®
MD_60A Operating Instructions
Complete parameter list
64_
Analog outputs optional
640
Analog output AO1
ACTUAL SPEED
The following functions can be programmed: NO FUNCTION
•
RAMP INPUT
•
SPEED SETPOINT
•
ACTUAL SPEED
•
ACTUAL
FREQUENCY
•
OUTPUT CURRENT
•
ACTIVE CURRENT
•
UNIT
UTILIZATION
•
IPOS OUTPUT
•
RELATED TORQUE
641
Scaling AO1
-10 – 0 – 1 – 10
642
Operating mode A01
OFF / -10 – +10V / 0 –
20mA / 4 – 20mA
643
Analog output AO2
OUTP.CURRENT
644
Scaling AO2
-10 – 0 – 1 – 10
645
Operating mode AO2
OFF / -10 – +10V / 0 –
20mA / 4 – 20mA
7__
CONTROL FUNCTIONS
70_
Operating Modes
700
Operating mode 1
VFC 1 VFC 1 & GROUP
VFC 1 & HOIST VFC 1
& DC BRAK. VFC 1
&FLY.START VFC-n-
CONTROL VFC-n-
CTRL.&GROUP VFC-n-
CTRL&HOIST VFC-n-
CTRL& SYNC VFC-n-
CTRL& IPOS VFC-n-
CTRL&DPx CFC
CFC&M-CONTROL
CFC& IPOS CFC&
SYNC. CFC& DPx
SERVO SERVO & M-
CTRL. SERVO & IPOS
SERVO & SYNC.
SERVO & DPx
701 Operating mode 2
VFC 2 VFC 2 & GROUP
VFC 2 & HOIST VFC 2
& DC BRAK. VFC 2
&FLY.START
71_
Current at standstill
710
Standstill current 1
0 – 50 % I
Mot
711 Standstill current 2
0 – 50 % I
Mot
72_
Setpoint stop function
720
Setpoint stop function
1
ON / OFF
723
Setpoint stop function
2
ON / OFF
721
Stop setpoint 1
0 – 30 – 500 rpm
724 Stop setpoint 2
0 – 30 – 500 rpm
722
Start offset 1
0 – 30 – 500 rpm
725 Start offset 2
0 – 30 – 500 rpm
73_
Brake function
730
Brake function 1
ON / OFF
733 Brake function 2
ON / OFF
731
Brake release time 1
0 – 2 s
734 Brake release time 2
0 – 2 s
732
Brake application time
1
0 – 0.2 – 2 s
735
Brake application time
2
0 – 0.2 – 2 s
74_
Speed skip
740
Skip window center 1
0 – 1500 – 5000 rpm
742 Skip window center 2
0 – 1500 – 5000 rpm
741
Skip width 1
0 – 300 rpm
743 Skip width 2
0 – 300 rpm
75_
Master-Slave function
750
Slave setpoint
MASTER-SLAVE OFF
SPEED (RS-485)
SPEED (SBus) SPEED
(485+SBus) TORQUE
(RS-485) TORQUE
(SBus)
TORQUE(485+SBus)
LOAD SHAR(RS-485)
LOAD SHARE (SBus)
LOAD S(485+SBus)
751
Scaling
Slave setpoint
-10 – 0 – 1 – 10
Par.
Name
Setting range
Factory setting
After
startup
Par.
Name
Setting range
Factory setting
After
startup
Variable par.
Parameter set 1
Parameter set 2
0
0
I
Содержание MOVIDRIVE MD*60A Series
Страница 3: ...MOVIDRIVE MD_60A Edition 09 2001 Operating Instructions 1053 2617 EN ...
Страница 4: ...SEW EURODRIVE ...
Страница 100: ...10 2000 ...
Страница 101: ...10 2000 ...