MOVIDRIVE
®
MD_60A Operating Instructions
55
Starting the motor
Fixed setpoints
The following table shows which signals must be present on terminals X13:1 – X13:6
(DIØØ – DIØ5) when the "UNIPOL/FIX.SETPT" setpoint is selected (P100), in order to
operate the drive with the fixed setpoints.
The following travel cycle shows by way of example how the drive is started with the wiring of terminals X13:1
– X13:6 and the internal fixed setpoints. Binary output X10:3 (DBØØ "/Brake") is used for switching brake
contactor K12.
Function
X13:1 (DIØØ)
/Ctrler inhibit
X13:2 (DIØ1)
CW/STOP
X13:3 (DIØ2)
CCW/STOP
X13:4 (DIØ3)
Enable/rapid stop
X13:5 (DIØ4)
n11/n21
X13:6 (DIØ5)
n12/n22
Controller inhibit
"0"
X
X
X
X
X
Rapid stop
"1"
X
X
"0"
X
X
Enable and stop
"1"
"0"
"0"
"1"
X
X
Clockwise at n11
"1"
"1"
"0"
"1"
"1"
"0"
Clockwise at n12
"1"
"1"
"0"
"1"
"0"
"1"
Clockwise at n13
"1"
"1"
"0"
"1"
"1"
"1"
C-clockw. at n11
"1"
"0"
"1"
"1"
"1"
"0"
05034AEN
Fig. 48: Travel cycle with internal fixed setpoints
The motor is not energized in the event of controller inhibit (DIØØ = "0"). A motor without
a brake then coasts to a halt.
"1"
"1"
"1"
"1"
"1"
"1"
"0"
"0"
"0"
"0"
"0"
"0"
n13
n12
-n12
-n13
0
"1"
"0"
n11
-n11
n [rpm]
Input DIØØ
/Controller inhibit
Input DIØ1
CW/stop
Input DIØ2
CCW/stop
Input DIØ3
Enable/
Rapid stop
Input DIØ4
n11/n21
Input DIØ5
n12/n22
Speed
Output DBØØ
/Brake
t11 CW up
t11 CW up
t11 CW up
t11 CW down
t11 CCW up
t13 stop ramp
0
0
I
Содержание MOVIDRIVE MD*60A Series
Страница 3: ...MOVIDRIVE MD_60A Edition 09 2001 Operating Instructions 1053 2617 EN ...
Страница 4: ...SEW EURODRIVE ...
Страница 100: ...10 2000 ...
Страница 101: ...10 2000 ...