66
MOVIDRIVE
®
MD_60A Operating Instructions
Operating displays
6
Operation and Servicing
6.1
Operating displays
7-segment
display
The 7-segment display shows the operating status of MOVIDRIVE
®
in hexadecimal
notation and, in the event of a fault, a fault or warning code.
DBG11A keypad
Basic displays:
Display
Meaning
0
Inverter not ready
1
Controller inhibit active
2
No enable
3
Current at standstill
4
VFC mode
5
n-control
6
M-control
7
Hold control
8
Factory setting
9
Limit switch reached
A
Technology option
b
Free
C
IPOS reference travel
d
Flying start
E
Free
F
Fault display (flashing)
→
page 294
H
Manual operation
t
Timeout active
→
page 293
CONTROL.INHIBIT
CURRENT:
0
A
Display when X13:1 (DIØØ "/CONTROL.INHIBIT") = "0".
NO ENABLE
CURRENT:
0
A
Display when X13:1 (DIØØ "/CONTROL.INHIBIT") = "1" and
inverter is not enabled ("ENABLE/RAPID STOP" = "0").
SPEED
942 rpm
CURRENT:
2.51 A
Display when inverter enabled.
NOTE XX
XXXXXXXXXXXXXXXXXXX
Information message
FAULT
XX
XXXXXXXXXXXXXXXXXXX
Fault indication
Содержание MOVIDRIVE MD*60A Series